TABLE 1
LED Name
Power Supply
Status
Power Status
System Status
Ethernet
Speed
Ethernet Link
Brocade 5100 Hardware Reference Manual
53-1000854-06
Brocade 5100 LED Patterns During Normal Operation
LED Color
Status of Hardware
No light
Primary power cord is disconnected or
is not actively powered, or power
supply has failed.
Steady green
Power supply is operating normally.
Flashing green (for
A power supply and fan assembly fault
more than five
has occurred for one of the following
seconds)
reasons:
No light
System is off or there is an internal
power supply failure.
Steady green
System is on and power supplies are
functioning properly.
No light
System is off, boot is not complete, or
boot failed.
Steady green
System is on and power supplies are
functioning properly.
Steady amber (for
Boot failed, the system is faulty.
more than five
seconds)
Flashing amber/
Attention is required. A number of
green
variables can cause this status
including a single power supply failure,
a fan failure, or one or more
environmental ranges has exceeded.
No light
Port speed is 10 Mbps.
Steady green
Port speed is 100 Mbps.
No light
There is no link.
The power supply or fan in the
assembly has failed.
The FRU was disabled by a user.
The FRU power switch has been
turned off or the unit has been
unplugged.
Brocade 5100 Operation
Recommended Action
Verify the power supply is on and
seated and the power cord is
connected to a functioning power
source.
No action required.
Take one of the following actions:
Replace the FRU
Verify that the power
supply/fan assembly FRU is
enabled
Check the power switch and
plug
Verify the system is on. If the
system is on, the unit is faulty.
Contact Technical Support.
No action required.
Verify the system is on and has
completed booting.
No action required.
Perform the following steps:
Connect a serial cable to the
system.
Reboot the system.
Check the failure indicated on the
system console.
Contact Technical Support.
Check the management interface
and the error log for details on the
cause of status.
Contact Technical Support if
required.
No action required.
No action required.
Verify the Ethernet cable is
connected correctly.