Electrical Connection; Wiring Diagrams; Instructions For Assembly Of Load Bearing Bottom Protection - Bertazzoni P34 5 00 X Installation, Service And User Instructions Manual

Built-in gas hotplates
Table of Contents

Advertisement

Available languages

Available languages

9. Sometimes the burners will not ignite immediately and seem to 'blow' slightly when they do ignite. This
usually due to air in the gas lines, which will clear itself within seconds.
10. If after following the instructions given, satisfactory performance cannot be obtained, contact the local
gas authority for advice and assistance.

Electrical connection

The connection of the hobs to mains is effected via the flex and the three pin plug located underneath the
hotplate. The appliance operate at a main voltage of 120V a.c., frequency 60Hz. Electric power absorption is
about 1W.
WARNING: Electrical Grounding Instructions: This appliance is equipped with a (three-prong)
grounding plug for your protection against shock hazard and should be plugged directly into a
properly grounded receptable. Do not cut or remove the grounding prong from this plug.

Wiring diagrams

Instructions for assembly of load bearing bottom protection

After the installation of the hob (5) proceed with the assembly of the load bearing bottom protection (2)
placing it in the position showed in picture and fixing it with screws supplied (1) with inserts (3) present on
the load bearing bottom (4).
Wiring diagram description
1. Cable terminal
2. Spark generator
3. Ignition spark
L. Black
N. White
T. Green (earth)
6
1 SCREW M5
2 LOAD BEARING
BOTTOM PROTECTION
3 RIVET M5
4 LOAD BEARING
BOTTOM
5 WORK TABLE