Installation Requirements; Electrical; Electrical Connection - Bertazzoni 3100768 Installation Manual & Users Manual

Induction rangetop
Table of Contents

Advertisement

/ Installation requirements / Electrical connection

INSTALLATION REQUIREMENTS

ELECTRICAL

A properly-grounded horizontally- mounted electri-
cal receptacle should be installed no higher than
27" (68.6 cm) above the fl oor, no less than 2" (5
cm) and no more than 15" (38,1 cm) from the left
side (facing product).
Check all local code requirements.
min 3" 7/16
max 5" 3/16
E
15"
installation area for the connection
10

ELECTRICAL CONNECTION

Warning!
ELECTRICAL SHOCK HAZARD
Disconnect electrical power at the circuit bre-
aker box or fuse box before installing the ap-
pliance.
Provide appropriate ground for the appliance.
Use copper conductors only.
Failure to follow these instructions could re-
sult in serious injury or death.
Warning!
Electrical grounding
This appliance is equipped with a 4 ft (1.2 m) fl exi-
ble metal cable with 3 wires ready for connection
to a dedicated 2 pole, 3 wires grounded power
supply.
The appliance shall be connected to an electric
line rated at 208Vac or 240Vac and 60Hz frequen-
cy.
Voltage
Appliance rating Electrical supply
208V
10000W 44A
240V
11500W 44A
3 Wires connection:
-Connect the L1 receptacle terminal to the inco-
ming BLACK electrical supply wire (L1-hot wire)
-Connect the L2 receptacle terminal to the inco-
ming RED electrical supply wire (L2-hot wire)
-Connect the GROUND receptacle terminal to the
incoming GROUND (GREEN) electrical supply
wire
Caution
Label all wires prior to disconnecting when
servicing controls. Wiring errors can cause
improper and dangerous operation.
Verify proper operation after servicing.
50A
50A