Connection - Ideal-Standard HYGIENE PLUS Manual For Use And Installation

Table of Contents

Advertisement

Available languages

Available languages

systems are not to standard or for work performed
by unqualifi ed or unskilled personnel.
The electrical specifi cation of the whirlpool
with the CE mark and relative rating plate val-
ues are given on the label on the edge of the
tub. Under no circumstances must this label
be removed.
F
IllIng oF bumPIng cIrcuIt
Fill the bumping circuit before installing the tub
(fi g.1) .
2
4
2-3 min.
252
252
TT0283660_05_PREMIUM_CMYK.indd 252
1
3
fi g.1
e
lectrIcal connectIon
ATTENTION!
Prior to installation, check that the electrical system
is compliant with standards and laws in eff ect and
that it is equipped with a magneto-thermal diff er-
ential switch with a breaking capacity of 16A and
a diff erential of 30mA. Connection must be made
in a fi xed and permanent manner, with no inter-
mediate connections, by installing an omnipolar
16A disconnecting switch with minimum aperture
distance of contacts which allows complete dis-
connection in conditions of category III, outside of
zones 0-1-2-3 and protected from water splashes
(60 cm laterally beyond the side of the tub or at
height of 225 cm from the fl oor). (Fig. 1)
Safety distances and clearances
Zone 1
Zone 0
Zone 2
Zone 3
Parts containing live components, with the excep-
tion of those parts powered at very low voltage
(i.e. not exceeding 12V) must not be accessible to
persons using the tub.
All parts containing electrical components, with
the exception of remote control handsets, must
be positioned or fi xed in such a way as to ensure
that they cannot fall into the tub. The power cable
must be protected inside the wall by a corrugated
tube or by another system that is compliant with
fi g.2