19
Travel limits regulate the points at which the door will stop
PROGRAM THE TRAVEL LIMITS AND FORCE SETTINGS
when moving UP or DOWN. The travel limit buttons are located
under the access cover on the rear panel (figure 1).
figure 1
NOTE: This opener uses a POSITION TAB attached to the belt
which activates a mechanical passpoint during the door travel.
The indicator LED will blink when this occurs. If the passpoint
is not activated during the door travel process, the travel limits
cannot be programmed.
TO PROGRAM THE TRAVEL LIMITS:
1. Press the PROG Button until the UP Arrow Button and indicator
LED begin to flash (figure 2).
2. Press and hold the UP Arrow Button until the door is in the
desired UP position (figure 3).
NOTE: The UP and DOWN Arrow Buttons can be used to move
the door up and down as needed.
3. Once the door is in the desired UP position press and release the
PROG Button. The DOWN Arrow Button will begin to flash (figure
4).
4. Press and hold the DOWN Arrow Button until the door is in the
desired DOWN position (figure 5).
NOTE: The UP and DOWN Arrow Buttons can be used to move
the door up and down as needed.
5. Once the door is in the desired DOWN position press and release
the PROG Button. The UP Arrow Button will begin to flash (figure
2).
SETTING THE FORCE (AUTO):
6. Press and release the UP Arrow Button to test the UP limit. When
the door has travelled to the programmed UP limit, the DOWN
Arrow Button will begin to flash.
7. Press and release the DOWN Arrow Button to test the DOWN
limit. The door will travel to the programmed DOWN limit.
The indicator LED will stop flashing. The travel limits and force
setting has now been set. Proceed to test safety reverse system.
SETTING THE FORCE (MANUAL LEARN IF REQUIRED):
1. Open the rear access panel. Locate the yellow Learn button.
2. Push the yellow Learn button twice to enter unit into force
adjustment mode. The LED (indicator light) will flash quickly.
3. Push the programmed remote control or push the UP/DOWN
arrow at the programming display bar. The door will travel to the
DOWN (close) position. Push the remote control again, the door
will travel to the UP (open) position.
4. Press and release the DOWN Arrow Button to test the DOWN
limit. The door will travel to the programmed DOWN limit.
The LED (indicator light) will stop flashing when the force has
been set. The door must travel through a complete cycle, UP
and DOWN, in order for the force to be set properly. If the unit
cannot open and close your door fully, inspect your door to insure
that it is not sticking or binding.
The Force Setting has now been set manually.
ADJUSTMENT SECTION
• Incorrect adjustment of garage door travel limits will
interfere with proper operation of safety reversal
system.
• NEVER use force adjustments to compensate for a
binding or sticking garage door.
• After ANY adjustments are made, the safety reversal
system MUST be tested. Door MUST reverse on
contact with 40 mm high object laid flat on floor.
To prevent damage to vehicles, be sure fully open
door provides adequate clearance.
figure 2
figure 3
figure 4
figure 5
11
Without a properly installed safety reversal
system, persons (particularly small children)
could be SERIOUSLY INJURED or KILLED by
a closing door.