(2) AI parenthesizing mode
In this mode, the scanner parenthesizes AIs contained in data read and output the edited data according to the
extraction conditions.
Extraction conditions
Extraction conditions
"Data transfer regardless of error result"
If the scanner fails to extract an AI-prefixed element string when the "Data transfer regardless of error result" is
permitted, it outputs the data read as is without editing.
Example Code ID mark: Disable, Header: STX, Terminator: ETX, Transmission of the number of digits: Disable,
BCC: Disable, Prefix/Suffix: None
Extraction conditions
"Data transfer regardless
of error result": Prohibit
"Data transfer regardless
of error result": Permit
(Note 1) Data from the head to element string 030810 prefixed with AI (13) can be normally extracted, but the
following data (as underlined below) causes an error since it starts with 6 that cannot start any AI.
(01)94901234567894(11)030808(13)03081061704020817040305
Choices
Permit/Prohibit
Data read
0194901234567894110308081303
081017040208
0194901234567894110308081303
081061704020817040305
0194901234567894110308081303
081017040208
0194901234567894110308081303
081061704020817040305
35
Output data
[STX](01)94901234567894(11)030808(13)03
0810(17)040208[ETX]
Error (Note 1)
[STX](01)94901234567894(11)030808(13)03
0810(17)040208[ETX]
[STX]01949012345678941103080813030
81061704020817040305[ETX]