Washer-Extractor Cabinet Hardmount Mechanical Timer Refer to Page 8 for Model Numbers CHM1624C Part No. F232202R2 www.comlaundry.com December 2006...
Safety Information Locating an Authorized Servicer Alliance Laundry Systems is not responsible for personal injury or property damage resulting from improper service. Review all service information before beginning repairs. Warranty service must be performed by an authorized technician, using authorized factory parts. If service is required after the warranty expires, Alliance Laundry Systems also recommends contacting an authorized technician and using authorized factory parts.
This will also test the function of the voltmeter. If 120 Volts** are present on both readings, continue to the next troubleshooting step. If 120 Volts** are not present on both readings, contact Alliance Laundry Systems’ Customer Service Department for assistance in locating the broken circuit.
This will also test the function of the voltmeter. If 120 Volts** are present on both readings, continue to the next troubleshooting step. If 120 Volts** are not present on both readings, contact Alliance Laundry Systems’ Customer Service Department for assistance in locating the broken circuit.
This will also test the function of the voltmeter. If 120 Volts** are present on both readings, continue to the next troubleshooting step. If 120 Volts** are not present on both readings, contact Alliance Laundry Systems’ Customer Service Department for assistance in locating the broken circuit.
KM2 spin contactor. This will also test the function of the voltmeter. If 120 Volts** are present on both readings, continue to the next troubleshooting step. If 120 Volts** are not present on both readings, contact Alliance Laundry Systems’ Customer Service Department for assistance in locating the broken circuit.
This will also test the function of the voltmeter. If 120 Volts** are present on both readings, continue to the next troubleshooting step. If 120 Volts** are not present on both readings, contact Alliance Laundry Systems’ Customer Service department for assistance in locating the broken circuit.
This will also test the function of the voltmeter. If 120 Volts** are present on both readings, continue to the next troubleshooting step. If 120 Volts** are not present on both readings, contact Alliance Laundry Systems’ Customer Service department for assistance in locating the broken circuit.