Outdoor Installation - Bosch C 1210 ES Applications Manual

Bosch therm tankless water heaters
Table of Contents

Advertisement

THERM Tankless Water Heater Applications Manual

7 Outdoor Installation

The models listed below are designed to be installed indoors.
However, they are approved for outdoor installation when installed
with the Outdoor Kit (part# BTOK):
830 ES
940 ES/ESO
C 1050 ES
C 1210 ES/ESC
Outdoor Kit (BTOK) installation:
The installation of this outdoor kit (BTOK) is required when
installing any of the above appliances outdoors.
Outdoor cap easily retrofi ts to these indoor models.
Exterior water piping should be protected if short term freezing
conditions could exist.
Not for use in areas routinely exposed to freezing temperatures.
Minimum clearances:
Ref.
Description
A
Directly below or adjacent to
an opening; operable
B
windows, doors and any fresh
air openings
C
From any adjacent wall
D
Below a gutter, sanitary
E
pipework, eaves or overhang
F
Above ground
From a gas meter or gas
G
regulator
Outdoor Installation Clearances
Source: NFPA 54 National Fuel Gas CodeANSI Z223.1
Installation on wood siding
BOSCH THERMOTECHNOLOGY CORPORATION
Installation on vinyl siding:
Min.
distances
≥ 1 ft
≥ 1 ft
≥ 3 ft
≥ 1 ft
≥ 3 ft
3½΄
≥12"
≥12"
Data subject to change without notice | 01.2011
| 13
≥12"

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents