Summary of Contents for Watts Premier ZERO WASTE RETRO
Page 1
Four Pump mounting screws, drain plug and four plas- tic nuts. Recommended Tools for Installation Sharp knife Channel lock 5/8” wrench Cressant wrench Philips screwdriver / Screw gun Watts Premier, Inc. Phone: 800-752-5582 1725 W. Williams Dr Fax: 623-931-0191 Phoenix, AZ 85027 www.wattspremier.com page 1 Rev 10/15/02...
Page 2
Installation Steps for Zero Waste Reverse Osmosis Retrofit Kit Note: RO unit must be installed a mimimun of 25 feet from hot water heater. Step 1 Turn off the hot (#1 in Fig. 1) and cold (#2 in Fig. 1) water supply lines to the sink at the angle stop valves.
Page 3
Reverse Osmosis Water Faucet Standard Sink Water Faucet Standard Sink Drain Membrane Flow Restrictor Serial # NSF Premier LEGEND Blue Tube = Reverse Osmosis Water Red Tube = System to Air Gap Water Reverse Osmosis Storage Tank Black Tube = Air Gap to Drain Water Green Tube = Incoming &...
Page 4
Shut down procedure for filter and membrane maintenance Step 1 Turn off hot and cold water supply lines, (close ice maker valve if it applies). Step 2 Unplug the pump from electrical outlet. Step 3 Open RO faucet to drain tank, leave faucet open. If unit has a ball valve on tank close the ball valve and tank does not have to be emptied.