HIGH ALTITUDE ORIFICE KIT SELECTION GUIDE
Table 5.1 - Propane Gas - 5501 to 6500 ft. Elevations - PD/BD, PDP/BDP, PSH/BSH, model series "D","H","I", & ,"O" ➀ ➁
Model
Type
30
50
PD/BD
30
50
Kit Suffix
-31
-106
Drill Size
54
49
Orifices in Kit
1
PDP/BDP
30
50
Kit Suffix
-31
-106
Drill Size
54
49
Orifices in Kit
1
Pressure
Switch in Kit
NO
NO
PSH/BSH
-
Kit Suffix
-
Drill Size
-
Orifices in Kit
-
Pressure
Switch in Kit
-
-
Kit Suffix
-
Drill Size
-
Orifices in Kit
-
-
Kit Suffix
-
Drill Size
-
Orifices in Kit
-
Table 5.2 - Propane Gas - 6501 to 7500 ft. elevations - PD/BD, PSH/BSH, model series "D", "H","I", & ,"O" ➀ ➁
Model
Type
30
50
PD/BD
30
50
Kit Suffix
-31
-106
Drill Size
54
49
Orifices in Kit
1
PDP/BDP
30
50
Kit Suffix
-31
-106
Drill Size
54
49
Orifices in Kit
1
Pressure
Switch in Kit
NO
NO
PSH/BSH
-
Kit Suffix
-
Drill Size
-
Orifices in Kit
-
Pressure
Switch in Kit
-
-
Kit Suffix
-
Drill Size
-
Orifices in Kit
-
-
Kit Suffix
-
Drill Size
-
Orifices in Kit
-
All conversion kits have the same base part number 3H33231, only the suffix of the part number changes by model size.
Does not include DFS, DBS, DCS, IFS, IBS, ICS.
Indoor Gravity Vented Duct Furnaces
DFG, DBG, DCG, IFG, IBG, ICG
Indoor Power Vented Duct Furnaces
DFP, DBP, DCP, IFP, IBP, ICP
Kit for DFP, DBP, DCP, IFP, IBP, ICP, 400 size only, also includes
a pressure switch.
75
100
125
130
75
100
125
-78
-59
-46
43
49
45
1
1
2
2
75
100
125
-503
-59
-46
43
49
45
1
1
2
2
YES
NO
NO
-
-
-
-
130
-
-
-
-
506
-
-
-
-
44
-
-
-
-
-
-
-
-
YES
-
75
100
125
-
-33
-45
-35
-
42
48
44
-
1
2
2
-
75
100
125
-
-33
-45
-35
-
42
48
44
-
1
2
2
75
100
125
130
75
100
125
-78
-59
-46
43
49
45
1
1
2
2
75
100
125
-503
-59
-46
43
49
45
1
1
2
2
YES
NO
NO
-
-
-
-
130
-
-
-
-
507
-
-
-
-
45
-
-
-
-
-
-
-
-
YES
-
75
100
125
-
-33
-45
-46
-
42
48
45
-
1
2
2
-
75
100
125
-
-33
-45
-46
-
42
48
45
-
1
2
2
Weatherproof Duct Furnaces
HFG, HBG, HCG, HDG, HPG, OFG, OBG, OCG, ODG, OPG,HFP, HBP, HCP, HDP, HPP, OFP, OBP, OCP, ODP, OPP
Model Size
150
170
175
200
-
150
-
175
200
-
-77
-
-109
-79
-
43
-
46
44
-
2
-
3
3
-
150
-
175
200
-
-77
-
-109
-79
-
43
-
46
44
-
2
-
3
3
-
NO
-
NO
NO
150
170
-
-
511
37
-
-
49
47
-
-
2
3
3
-
-
YES
NO
-
-
-
150
-
175
200
-
-47
-
-63
-38
-
48
-
45
43
-
3
-
3
3
-
150
-
175
200
-
-47
-
-63
-38
-
48
-
45
43
-
3
-
3
3
Model Size
150
170
175
200
-
150
-
175
200
-
-77
-
-37
-63
-
43
-
47
45
-
2
-
3
3
-
150
-
175
200
-
-77
-
-37
-63
-
43
-
47
45
-
2
-
3
3
-
NO
-
NO
NO
150
170
-
-
511
512
-
-
49
47
-
-
2
3
3
-
-
YES
YES
-
-
-
150
-
175
200
-
-47
-
-63
-79
-
48
-
45
44
-
3
-
3
3
-
150
-
175
200
-
-47
-
-63
-79
-
48
-
45
44
-
3
-
3
3
75-535.11
225
250
280
300
340
-
250
-
300
-
-
-48
-
-40
-
-
41
-
43
-
-
3
-
4
-
-
250
-
300
-
-
-48
-
-40
-
-
41
-
43
-
-
3
-
4
-
-
NO
-
NO
-
225
-
280
-
340
517
-
520
-
525
43
-
43
-
44
3
-
4
-
5
YES
-
YES
-
YES
225
250
-
300
-
-39
-72
-
-49
-
42
44
-
42
-
3
4
-
4
-
225
250
-
300
-
-39
-72
-
-49
-
42
44
-
42
-
3
4
-
4
-
225
250
280
300
340
-
250
-
300
-
-39
-
-40
-
42
-
43
-
3
-
4
-
250
-
300
-
-39
-
-40
-
42
-
43
-
3
-
4
-
NO
-
NO
225
-
280
-
340
517
-
521
-
525
43
-
44
-
44
3
-
4
-
YES
-
YES
-
YES
225
250
-
300
-39
-119
-
-49
42
45
-
42
3
4
-
4
225
250
-
300
-39
-119
-
-49
42
45
-
42
3
4
-
4
350
400
350
400
-42
-86
43
44
5
6
350
400
-42
-86
43
44
5
6
NO
NO
-
-
-
-
-
-
-
-
-
-
350
400
-74
-51
45
43
6
6
350
400
-74
-528➄
45
43
6
6
350
400
-
350
400
-
-99
-74
-
44
45
-
5
6
-
350
400
-
-99
-74
-
44
45
-
5
6
-
NO
NO
-
-
-
-
-
-
5
-
-
-
-
-
350
400
-
-74
-86
-
45
44
-
6
6
-
350
400
-
-74
-529➄
-
45
44
-
6
6
5

Advertisement