Flash ROM Software Update
6. Type u and press <Enter>. The following messages will display:
Software Upload initiated...
SRAM (512 K-bytes) allocation succeeded...
Software in bank 1 will be erased now...
Please, wait...
Bank 1 erasure is completed...
Please, start Z-modem transfer...
Upload with baud rate [19200 bps]
To continue, please type Yes [y], or No [n]:
7. Type y to start the Flash ROM update. The following message will display:
Upload file with zmodem...
8. Use one of the following methods to set the file location and protocol.
For Hyper Terminal:
a. Use the "transfer" panel to select the "send file" option
b. Then select the object code file to be uploaded to the XTS-IP.
c. Select the "Zmodem" protocol, then click "Send".
-or-
For ECOM:
a. Use the "files" panel to select the "upload" option.
b. Then select the "Zmodem" upload protocol and click "OK".
c. Select the object code file to be uploaded to the XTS-IP, then click "OK".
After the upload is complete, the following messages will display:
Upload succeeded!
Please, wait until bank data programming is finished...
Z-modem transfer completed...
Uploaded software lies in bank 1...
Do you want to switch the banks of flash ROM now (y/n)?
XTS-IP - Installation Manual
Any loss of power or manual reset of the system at this point in the upgrade
process (during bank switching) will render the system inoperable.
Chapter 4 - Maintenance and Troubleshooting
4-27
December 2005