Table Of Contents; First Of All; Safety Considerations; Safety Precaution - Daikin RXYQ72PYDN Installation Manual

Vrv iii system air conditioner
Hide thumbs Also See for RXYQ72PYDN:
Table of Contents

Advertisement

RXYQ72PYDN
RXYQ96PYDN
RXYQ120PYDN
RXYQ144PYDN
CONTENTS
1. FIRST OF ALL..........................................................................1
1-1. Safety considerations ........................................................1
1-2. Special notice of product ...................................................2
1-3. Disposal requirements.......................................................3
2. INTRODUCTION......................................................................3
2-1. Combination ......................................................................3
2-2. Standard supplied accessories .........................................3
2-3. Option accessory...............................................................3
2-4. Technical and Electrical specifications..............................3
2-5. Main components ..............................................................3
3. SELECTION OF LOCATION....................................................3
4. INSPECTING AND HANDLING THE UNIT..............................4
5. PLACING THE UNIT ................................................................4
6. REFRIGERANT PIPING ..........................................................5
Refrigerant branching kit ...................................................5
6-3. Pipe connection.................................................................5
6-4. Connecting the refrigerant piping ......................................5
6-5. Example of connection ......................................................8
7. FIELD WIRING.......................................................................11
7-3. Leading wire Procedure ..................................................11
7-5. Power Wiring Connection Procedure ..............................12
7-6. Procedure for Wiring Inside Units....................................12
8. AIR TIGHT TEST AND VACUUM DRYING ...........................13
9. PIPE INSULATION.................................................................13
INSTALLATION CONDITIONS ..............................................14
CHECK OPERATION.............................................................14
11-1.Before working ...............................................................14
12. ONSITE SETTINGS ...............................................................18
13. TEST RUN .............................................................................18
13-1.Before test run................................................................18
13-2.Test Run.........................................................................18
13-3.Checks After Test Run ...................................................18
14. CAUTION FOR REFRIGERANT LEAKS ...............................19
1.

FIRST OF ALL

• This document is an installation manual for the Daikin RXYQ-P
Series VRV Inverter. Before installing the unit, read this manual thor-
oughly, and following the instructions contained in it.
After installation, do a test run to make sure the unit runs properly,
and then explain how to operate and take care of the unit to the cus-
tomer, using the operation manual.
Lastly, make sure the customer keeps this manual, along with the
operation manual, in a safe place.

1-1 Safety considerations

Please read these "SAFETY CONSIDERATIONS" carefully before
installing air conditioning unit and be sure to install it correctly. After
completing the installation, make sure that the unit operates properly
during the start-up operation. Please instruct the customer on how to
operate the unit and keep it maintained.
Also, inform customers that they should store this installation manual
along with the operation manual for future reference.
This air conditioner comes under the term "appliances not accessible to
the general public".
English
RXYQ168PYDN
RXYQ192PYDN
RXYQ216PYDN
RXYQ240PYDN
VRVIII System air conditioner

〈Safety Precaution〉

VRV System is a class A product. In a domestic environment this prod-
uct may cause radio interference in which case the user may be
required to take adequate measures.
Meaning of danger, warning, caution and note symbols.
DANGER .................... Indicates an imminently hazardous situa-
WARNING .................. Indicates a potentially hazardous situation
CAUTION.................... Indicates a potentially hazardous situation
NOTE .......................... Indicates a situation that may result in the
DANGER
• Refrigerant gas is heavier air and replaces oxygen. A massive
leak could lead to oxygen depletion, especially in basements,
and an asphyxiation hazard could occur leading to serious
injury or death.
• Do not ground units to water pipes, telephone wires or light-
ning rods because incomplete grounding could cause a se-
vere shock hazard resulting in severe injury or death, and to
gas pipes because a gas leak could result in an explosion
which could lead to severe injury or death.
• If the refrigerant gas leaks during installation, ventilate the
area immediately.
Refrigerant gas may produce toxic gas if it comes in contact with fire
such as from a fan, heater, stove or cooking device. Exposure to this
gas could cause severe injury or death.
• After completing the installation work, check that the refriger-
ant gas does not leak.
Refrigerant gas may produce toxic gas if it comes in contact with fire
such as from a fan, heater, stove or cooking device. Exposure to this
gas could cause severe injury or death.
• Do not install unit in an area where flammable materials are
present due to risk of explosion resulting in serious injury or
death.
• Safely dispose of the packing materials.
Packing materials, such as nails and other metal or wooden parts,
may cause stabs or other injuries.
Tear apart and throw away plastic packaging bags so that children will
not play with them. Children playing with plastic bags face the danger
of death by suffocation.
WARNING
• Ask your dealer or qualified personnel to carry out installation
work. Do not try to install the unit by yourself.
Improper installation may result in water leakage, electric shocks or fire.
• Perform installation work in accordance with this installation
manual.
Improper installation may result in water leakage, electric shocks or fire.
• When installing the unit in a small room, take measures
against to keep refrigerant concentration from exceeding al-
lowable safety limits in the event of refrigerant leakage.
Contact the place of purchase for more information. Excessive refrig-
erant in a closed ambient can lead to oxygen deficiency.
• Be sure to use only the specified accessories and parts for in-
stallation work.
Failure to use the specified parts may result in water leakage, electric
shocks, fire or the unit falling.
Installation manual
tion which,if not avoided, will result in death
or serious injury.
which, if not avoided, could result in death
or serious injury.
which, if not avoided, may result in minor or
moderate injury. It may also be sued to
alert against unsafe practices.
unit or property-damage-only accidents.
1

Hide quick links:

Advertisement

Table of Contents
loading