Photometric Chart; Power Supply - Elation EPAR QA User Instructions

Hide thumbs Also See for EPAR QA:
Table of Contents

Advertisement

EPAR QA
EPAR QA
Photometric Beam Angle Data
Standard 10° Beam Angle
LUX x 0.0929 = FC
R
267 FC / 2871 LUX
64 FC / 691 LUX
G
351 FC / 3774 LUX
94 FC / 1011 LUX
B
42 FC / 450 LUX
13 FC / 137 LUX
A
165 FC / 1774 LUX
51 FC / 553 LUX
ALL
727 FC / 7830 LUX
191 FC / 2060 LUX
0 m
0 ft
1 m
3.28 ft
EPAR QA
Beam Diameter
10° Beam Angle
Ø 0.24 m / Ø 0.79 ft
Ramp Effect
Unit Dim Mode
Standard
Stage
TV
Architectural
Theatre
Elation Professional - www.elationlighting.com - EPAR QA Instruction Manual Page 16

Photometric Chart

33 FC / 350 LUX
40 FC / 428 LUX
6 FC / 62 LUX
24 FC / 259 LUX
91 FC / 981 LUX
2 m
3 m
6.56 ft
9.84 ft
Dimmer Curve Diagram
Ø 0.48 m / Ø 1.57 ft
Ø 0.72 m / Ø 2.36 ft
(Fade Time)
EPAR QA
ower Supply:
P
switch, which will auto sense the voltage when it is plugged into the
power source. With this switch there is no need to worry about the cor-
rect power voltage, this unit can be plugged in anywhere.
DMX-512:
DMX is short for Digital Multiplex. This is a universal pro-
tocol used by most lighting and controller manufactures as a form of
communication between intelligent fixtures and controllers. A DMX
controller sends DMX data instructions from the controller to the fix-
ture. DMX data is sent as serial data that travels from fixture to fixture
via the DATA "IN" and DATA "OUT" XLR terminals located on all DMX
fixtures (most controllers only have a DATA "OUT" terminal).
DMX Linking: DMX is a language allowing all makes and models of
different manufactures to be linked together and operate from a single
controller, as long as all fixtures and the controller are DMX compli-
ant. To ensure proper DMX data transmission, when using several
DMX fixtures try to use the shortest cable path possible. The order
in which fixtures are connected in a DMX line does not influence the
DMX addressing. For example; a fixture assigned a DMX address of 1
may be placed anywhere in a DMX line, at the beginning, at the end,
or anywhere in the middle. When a fixture is assigned a DMX address
of 1, the DMX controller knows to send DATA assigned to address 1
to that unit, no matter where it is located in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX Operation):
The EPAR QA has 6 DMX Channel Modes. The DMX address is set
electronically using the controls on the rear panel of the unit. Your unit
and your DMX controller require a approved DMX-512 110 Ohm Data
cable for data input and data output. We recommend Accu-Cable DMX
cables. If you are making your own cables, be sure to use standard
110-120 Ohm shielded cable (This cable may be
purchased at almost all professional sound and
lighting stores). Your cables should be made with
a male and female XLR connector on either end of
the cable. Also remember that DMX cable must be
(Fade Time)
daisy chained and cannot be split.
Elation Professional - www.elationlighting.com - EPAR QA Instruction Manual Page 5
The Elation EPAR QA contains a automatic voltage
Set Up
Figure 1

Advertisement

Table of Contents
loading

Table of Contents