Photometric Chart; Troubleshooting - Elation Arena Par User Instructions

Table of Contents

Advertisement

Arena Par
©Elation Pr
fessionals® - www.elationlighting.com - Arena Par Instruction Manual Page 19
o

Photometric Chart

Arena Par
First unplug the power. Locate and remove the unit's power cord.
Once the cord has been removed located the fuse holder located
inside the power socket. Insert a flat-head screw driver into the power
socket and gently pry out the fuse holder. Remove the bad fuse and
replace with a new one. The fuse holder has a built-in socket for a
spare fuse be sure not to confuse the spare fuse with active fuse.
Arena Par
Fixture Cleaning:
Due to fog residue, smoke, and dust cleaning the
internal and external optical lenses and mirror should be carried out
periodically to optimize light output. Cleaning frequency depends on
the environment in which the fixture operates (I.e. smoke, fog residue,
dust, dew). In heavy club use we recommend cleaning on a monthly
basis. Periodic cleaning will ensure longevity, and crisp output.
1. Use normal glass cleaner and a soft cloth to wipe down the out-
side casing.
2. Use a brush to wipe down the cooling vents and fan grill.
3. Clean the external optics and mirror with glass cleaner and a soft
cloth every 20 days.
4. Clean the internal optics with glass cleaner and a soft cloth every
30-60 days.
5. Always be sure to dry all parts completely before plugging the unit
back in.
Arena Par
Trouble Shooting: Listed below are a few common problems that
you may encounter, with solutions.
No light output from the unit;
1. Be sure the external fuse has not blown. The fuse is located on
the rear panel of the unit, inside the power socket. Please see
Fuse Replacement above.
2. Be sure the fuse holder is completely and properly seated.
©Elation Pr
fessionals® - www.elationlighting.com - Arena Par Instruction Manual Page 20
o
Fuse Replacement