EQUIPMENT SAFETY FEATURES

Automatic Time Outs

Your PowerPool™ is equipped with an
automatic Time Out feature designed to
protect both the equipment and the user.
For your safety and to reduce unnecessary
use of the pumps and lights, the Time
Out feature turns selected accessories off
automatically, as follows:
Common LCD Equipment Safety Messages and Trouble Shooting
The following table describes the most common messages, possible causes, and corrective
actions you may need to take:
If the LCD
displays...
Indicates...
OHH
Overheat - one
of the sensors
has detected
water tempera-
ture of 118°F+
(48°C+) inside
the heater
OHS
Overheat
- One sensor
has detected
temperature
of PowerPool™
water entering
heater to be
108°F+ (42°C+)
HFL
Heater flow
problem
23
PowerPool™
What happens...
PowerPool™ heater
will automatically
shut down until
temperature falls
below 108°F+ (42°C+)
PowerPool™ heater
will automatically
shut down until
temperature falls be-
low 108°F+ (42°C+)
Heater will shut down
while PowerPool™
continues to function
normally
Accessory
Pump 1
Pump 1
Pump 2
Pump 2
Pump 3
Pump 3
Underwater light
DOL Light
Possible cause...
- Low speed pump
operating for an ex-
tended period of time
- Programming error
causing continuous
filtering
- Faulty Pump
- Low speed pump
operating for an
extended period
of time
- Programming error
causing continuous
filtering
- Plugged filter
- Low water
Mode
Shuts off in...
Low
4 hours
High
15 minutes
Low
15 minutes
High
15 minutes
Low
15 minutes
High
15 minutes
1 hour
1 hour
Corrective action...
- Make sure slice valves
are open
- Reprogram to ensure
time cycles are not
overlapping
- Contact dealer if
problem persists
- Make sure slice valves
are open
- Reprogram to ensure
time cycles are not
overlapping
- Contact dealer if
problem persists
- Remove filter and clean
- Add water
- Contact dealer