Configuration.mode - ICM Controls SC 3801 Installation, Operation & Application Manual

Programmable electronic 2 heat/2 cool 7-day programmable hardwired
Hide thumbs Also See for SC 3801:
Table of Contents

Advertisement

The.configuration.mode.is.used.to.set.the.SC3801.to.match.your.heating/cooling.system..The.SC3801.functions.
with.heat.pump,.air.conditioning,.gas,.oil,.or.electric.heat.systems.
1.. To.enter.the.configuration.mode,.simultaneously.hold.down.the.
SC3801.is.in.OFF.mode.
2.. Press.the.
.or.
.button.to.change.settings.within.each.screen.
3.. Press.the. .button.to.advance.to.the.next.screen.
.
. Note:.The. .button.will.return.you.to.the.previous.screen.
4.. To.exit.configuration.mode,.hold.in.the. .button.for.6.seconds.
Configuration Mode Settings..
The.setup.screens.for.configuration.mode.are.as.follows:
1.. Heat.pump.–.Press.the.
.
•.ON.=.Heat.pump.system
.
•.OFF.=.Non-heat.pump.system
.
Press.the. .button.to.advance.to.the.next.screen.
2.. Reversing.valve.–.appears.only.if.heat.pump.is.set.to."ON".
.
Press.the.
.or.
.button.to.set.reversing.valve.
.
If.your.reversing.valve.is.energized.in.heat.mode,.set.to."b.".If.the.reversing.valve.is.
energized.in.cool.mode,.set.to."o."
.
Press.the. .button.to.advance.to.the.next.screen.
3.. HEAT,.ELECTRIC,.or.GAS/OIL.–.appears.only.if.heat.pump.setting.is."OFF".
.
Press.the.
.or.
.button.to.set.heat.type.
.
•.For.electric.heat.(interlocked),.set."ELC".ON
.
•.For.gas.or.oil.heat.(non-interlocked),.toggle."ELC".OFF
.
Press.the. .button.to.advance.to.the.next.screen.
Configuration Mode
.or.
.button.to.configure.as.heat.pump.or.non-heat.pump.system.
.and.
.buttons.while.the.


Hide quick links: