Configuration Mode - ICM Controls SC 5811 Manual

2 heat/2 cool auto changeover hardwire programmable electronic thermostat
Table of Contents

Advertisement

The configuration mode is used to set the SC5811 to match your heating/cooling system . The SC5811
functions with heat pump, air conditioning, gas, oil or electric heat systems .
To configure the SC5811, perform the following steps:
1 . Verify the SC5811 is in the OFF mode .
Press the SYS (left) button until off mode displays .
2 . Remove the cover of the thermostat by gently pulling near one of the
corners at the top of the thermostat .
3 . Press the CONFIG button for 1 second while the SC5811 is in OFF mode .
Press the up or down button to change settings within each screen .
Press the right button to advance to the next screen .
Note: Pressing the left button will return you to the previous screen .
To exit configuration mode, press the CONFIG switch for 1 second .

Configuration Mode

PM
OFF
CONFIG
S1 S2 R
C
W
Y1 W2
Y2
G
W3
FP
O/B
RESET
CONFIG
Up
button
Down
button
Left
Right
button
button


Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents