Installing and Changing Batteries

For Battery Thermostat Operation
If your LCD is blank, or displaying LO BAT, the batteries are not installed or
need to be changed. We suggest you change the batteries at least once a year,
or whenever the LO BAT warning displays.
Remove the cover, and install the two "AAA" alkaline batteries into the battery
compartment. Proper battery installation is important! Make sure the positive
ends of the batteries match the positive terminals in the battery compartment.
For Hardwired Thermostat Operation
Batteries are not required when a common wire is connected to the C terminal of the SC2010 N/L
thermostat.

Configuration Mode

The configuration mode is used to set the SC2010 N/L to match your system.
To configure the SC2010 N/L, perform the following steps:
1. Verify the SC2010 N/L is in the OFF mode.
Slide the system switch to the center position until off mode displays.
2. Remove the cover of the thermostat by gently pulling near one of the
corners at the top of the thermostat.
3. Press both the LEFT and RIGHT switches for 1 second while the SC2010 N/L is in OFF mode.
Press the up or down button to change settings within each screen.
Press the RIGHT switch to advance to the next screen.
Note: Pressing the LEFT switch will return you to the previous screen.
To exit configuration mode, press both the LEFT and RIGHT switches for 1 second or slide the mode
switch to heat or cool.

Configuration Mode Settings

The setup screens for Configuration Mode are as follows:
1. Temperature Scale (F or C) – Choose Fahrenheit or Celsius.
Press the up or down button to select.
Press the RIGHT switch to advance to the next screen.
2. Temperature Differential (1°F to 5°F) (1°C to 3°C) – Set the number
of degrees between your "setpoint" temperature and your "turn on"
temperature.
Press the up or down button to set differential value.
Press the RIGHT switch to advance to the next screen.
3. Heat Pump and Non-Heat Pump – Set to heat pump, or non-heat pump
system. For heat pumps, there will be a compressor time delay for heating
and cooling.
• 1 = Heat pump system
• 0 = Non-heat pump system
Press the up or down button to select.
Press the RIGHT switch to advance to the next screen.
4. Lockout (0°F-8°F) (0°C-8°C) – Select the number of degrees set
temperature can be changed during keypad lockout
Press the up or down button to select.
Press the RIGHT switch to advance to the next screen.
5. Maximum Heat Setpoint (45°F to 90°F) (7°C to 32°C)
Adjust to control the maximum heat set temperature allowed.
Press the up or down button to select.
Press the RIGHT switch to advance to the next screen.
6. Minimum Cool Setpoint (45°F to 90°F) (7°C to 32°C)
Adjust to control the minimum cool set temperature allowed.
Press the up or down button to select.
Press the RIGHT switch to advance to the next screen.
7. Room Temperature Offset (+9°F to -9°F) (+5°C to -5°C)
Adjust to calibrate displayed room temperature to match actual room
temperature.
Press the up or down button to select.
Press the RIGHT switch to advance to the next screen.
8. Maximum Cycles Allowed Per Hour (- -, 2-6)
- - = as many as needed, 2-6 = maximum cycles/hour
Press the up or down button to select.
Press the RIGHT switch to advance to the next screen.
9. Back Light (0 or 1) (Note: For SC2010L only)
0 = Back light never on (best for long battery life)
1 = Back light on when button pressed
Press the up or down button to select.
To exit configuration mode, press both the LEFT and RIGHT switches for 2 seconds or slide the
mode switch to heat or cool.

Operating Modes

OFF Mode
• In this mode, the thermostat will not turn on the heating or cooling devices (manual fan can operate)
• OFF mode is also used to access the configuration screens
Cool Mode
• In this mode, the thermostat controls the cooling system
Heat Mode
• In this mode, the thermostat controls the heating system

Lockout Feature

The SC2010 N/L has a button lockout feature so the temperature adjustment is
prohibited or limited. Select the appropriate lockout from Configuration Mode Settings
(Step 4) of this guide.
To activate the LOC feature:
1. Simultaneously press the LEFT, RIGHT and UP buttons for 10 seconds.
2. LOC will display and the lockout function will be enabled.
To deactivate the LOC feature, repeat steps 1 and 2 above.
SimpleSet
This feature is used for transferring the configuration settings from the master to the target
thermostat. All thermostats for a job can be mounted and powered up. Configure one thermostat. This
will be the master. The master will be used to copy the configuration to the rest of the thermostats.
Preparing the master to Send:
1. The master must be powered by 24 VAC or batteries.
2. Verify the master thermostat is in OFF mode. Slide system switch to center
position.
3. Remove cover of the master thermostat by gently pulling near one of the corners
at the top of the thermostat.
4. Press the up and down buttons and RIGHT switch simultaneously for 5
seconds.
5. The OUT screen displays indicating the master thermostat is ready to
transfer data.
Note: Press the up and down buttons and RIGHT switch simultaneously for
5 seconds to exit from data transfer mode and to return the master to
the OFF mode.
6. Connect the master to the target using the 3 wire connector. Attach one end to
the Master's FP pins and the other end to the Target's FP pins.
Note: Target thermostat must be powered by 24 VAC or batteries for field programming to
occur.
When the connection has been made correctly, the master thermostat will power up and the target will
count from 6 down to 1. It will then display LOC confirming the data has been saved in memory.
When all target thermostats have been completed, reinstall the master thermostat.
Press the up and down buttons and the RIGHT switch simultaneously for 5 seconds to exit from the
data transfer mode and to return the master thermostat to the OFF mode.

Troubleshooting

Symptom
No display
Check for 24 VAC at thermostat; display is blank when 24 VAC
is not present or if batteries are completely discharged
System fan does not come on
Verify wiring is correct, check Gas/Electric jumper position (see
properly
Parts Diagram)
All thermostat buttons are
Verify 24 VAC is present; unit locks out when 24 VAC is not
inoperative
present with no batteries installed
No response with first button
First button press activates backlight only when back light is
press
configured "ON" (see Configuration Mode Setting 9)
Heat or Cool not working
RC/RH jumper must be installed on single transformer systems
For heat pumps, Non-HP jumper must be on HP pins
Thermostat turns on and off too
Adjust temperature differential
frequently
(see Configuration Mode Setting 2)
Fan runs continuously
Slide FAN switch to auto to turn fan off
Room temperature is not correct
Calibrate thermostat (see Configuration Mode Setting 7)
LOC displays when any button
Thermostat has the button lockout function activated (see
is pressed
Lockout Feature and Configuration Mode Setting 4)
Heat or Cool not coming on
Verify wiring is correct, verify RC/RH jumper is in place (for
single transformer system)
on display
Replace batteries with two fresh "AAA" alkaline batteries
Problem not listed above
Press Reset button once*
* Reset Button Function: Configuration settings are unchanged.
ONE-YEAR LIMITED WARRANTY
The Seller warrants its products against defects in material or workmanship for a period of one (1) year
from the date of manufacture. The liability of the Seller is limited, at its option, to repair, replace or issue a
non-case credit for the purchase prices of the goods which are provided to be defective. The warranty and
remedies set forth herein do not apply to any goods or parts thereof which have been subjected to misuse
including any use or application in violation of the Seller's instructions, neglect, tampering, improper storage,
incorrect installation or servicing not performed by the Seller. In order to permit the Seller to properly
administer the warranty, the Buyer shall: 1) Notify the Seller promptly of any claim, submitting date code
information or any other pertinent data as requested by the Seller. 2) Permit the Seller to inspect and test
the product claimed to be defective. Items claimed to be defective and are determined by Seller to be non-
defective are subject to a $30.00 per hour inspection fee. This warranty constitutes the Seller's sole liability
hereunder and is in lieu of any other warranty expressed, implied or statutory. Unless otherwise stated
in writing, Seller makes no warranty that the goods depicted or described herein are fit for any particular
purpose.
Patent No. 424,953
7313 William Barry Blvd., North Syracuse, NY 13212
(Toll Free) 800-365-5525 (Phone) 315-233-5266 (Fax) 315-233-5276
www.icmcontrols.com
Field Programming
TM
Remedy
SC2010 N/L
FP Pins
LIAF019

Advertisement

loading