Programming (continued)
•.Set.time.is.displayed
9.. Press.the. .or. .button.to.change.set.time..
10.. Press.the. .button.to.advance.to.the.next.screen.
.
. Note:. Transitions.required.after.11:59.PM.must.be.programmed.in.the.next.
day's.MORN.period.
•.Heat.temperature.is.displayed.(50°F.to.90°F)
11.. Press.the. .or. .button.to.adjust.heat.set.temperature..
12.. Press.the. .button.to.advance.to.the.next.screen.
•.Cool.temperature.is.displayed.(45°F.to.85°F)
13.. Press.the. .or. .button.to.adjust.cool.set.temperature.
14.. Press.the. .button.to.advance.to.the.next.screen.
•.Programmable.fan.is.displayed
15.. Press.the. .or. .button.to.turn.ON/OFF.continuous.indoor.fan.for.that.period.
16.. Press.the. .button.to.advance.to.the.next.screen.
Repeat.steps.1-16.to.program.each.day.of.the.week.individually.or.use.the.
Simpleset
®
.feature.(see.Page.29).to.program.every.day.the.same.as.Monday.
Press.the. .button.for.5.seconds.to.exit.programming.and.return.to.the.OFF.mode.
Press.the. .button.to.select.the.correct.operating.mode.
Press.the. .button.to.enter.and.exit.program.mode..PROG.displays.when.in.program.mode.