Carrier WeatherMaker 48TC Series Product Data page 54

Carrier gas heat/electric cooling packaged rooftop 3 to 15 nominal tons
Hide thumbs Also See for WeatherMaker 48TC Series:
Table of Contents

Advertisement

Table 33 – COOLING CAPACITIES
TEMP (F) AIR ENT
CONDENSER (Edb)
TC
204.4
SHC
98.9
75
kW
11.57
TC
189.2
SHC
79.5
85
kW
12.59
TC
174.0
SHC
60.0
95
kW
13.68
TC
158.8
SHC
40.5
105
kW
14.67
TC
143.6
SHC
21.0
115
kW
15.77
TEMP (F) AIR ENT
CONDENSER Edb)
4500
TC
83.75
SHC
37.50
80
kW
10.50
TC
85.00
SHC
40.00
75
kW
10.16
TC
86.15
SHC
42.10
70
kW
9.84
TC
88.90
SHC
46.80
60
kW
9.37
TC
91.70
SHC
51.50
50
kW
9.12
TC
94.45
SHC
56.30
40
kW
9.05
LEGEND
Edb --- Entering Dry--- Bulb
Ewb --- Entering Wet--- Bulb
kW
--- Compressor Motor Power Input
Idb
--- Leaving Dry--- Bulb
Iwb
--- Leaving Wet--- Bulb
SHC --- Sensible Heat Capacity (1000 Btuh) Gross
TC
--- Total Capacity (1000 Btuh) Gross
2- - STAGE COOLING
48TC*E16 Cooling Capacities, Subcooling Mode
4500/0.02
72
67
62
186.3
168.2
118.1
137.2
11.22
10.77
171.7
154.1
103.4
127.3
12.24
11.81
157.0
140.0
88.7
117.5
13.35
12.86
142.3
125.8
74.1
107.7
14.41
13.88
127.6
111.7
59.4
97.8
15.38
14.88
48TC*E 16 COOLING CAPACITIES, HOT GAS REHEAT MODE
75 Dry Bulb
62.5 Wet Bulb
(50% Relative)
6000
7500
84.85
88.95
42.80
55.10
11.49
11.60
86.00
90.50
45.00
57.30
11.15
11.25
87.35
91.50
47.50
59.80
10.83
10.94
90.10
94.25
52.30
64.60
10.36
10.44
92.80
97.00
57.10
69.40
10.09
10.16
95.60
99.80
61.40
73.70
10.02
10.10
AIR ENTERING EVAPORATOR --- CFM
6000/0.06
Air Entering Evaporator --- Ewb (F)
72
67
218.4
199.6
114.8
133.7
11.78
11.45
203.0
184.8
96.5
120.2
12.81
12.50
187.6
170.1
78.2
106.8
13.91
13.57
172.2
155.3
59.9
93.3
14.90
14.55
156.8
140.5
41.6
79.9
15.88
15.65
AIR ENTERING EVAPORATOR --- Ewb (F)
75 Dry Bulb
64 Wet Bulb
(56% Relative)
Air Entering Evaporator --- Cfm
4500
6000
86.65
91.90
30.90
40.40
10.56
10.65
88.05
93.60
33.20
42.30
10.21
10.31
89.20
94.30
35.50
45.30
10.02
10.13
92.00
97.10
40.20
50.10
9.42
9.52
94.80
99.90
44.80
54.80
9.17
9.28
97.45
102.55
49.70
59.20
9.10
9.21
NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:
t
= t
ldb
edb
t
= Wet--- bulb temperature corresponding to enthalpy of air
lwb
leaving evaporator coil (h
h
= h
lwb
ewb
Where: h
= Enthalpy of air entering evaporator coil
ewb
54
7500/0.05
62
72
67
180.9
229.6
210.4
152.6
127.6
146.2
11.00
12.06
11.64
166.7
214.1
195.5
144.0
110.2
133.7
12.03
13.05
12.66
152.5
198.6
180.6
135.3
92.9
121.3
13.05
14.15
13.75
138.3
183.1
165.7
126.7
75.5
108.8
14.10
15.15
14.73
124.1
167.6
150.9
118.1
58.1
96.3
15.10
16.12
15.84
75 Dry Bulb
65.3 Wet Bulb
(60% Relative)
7500
4500
6000
92.90
87.90
91.75
44.50
24.80
29.30
11.70
11.60
11.72
94.65
89.20
93.45
46.90
26.90
31.50
11.33
11.26
11.35
96.10
90.40
94.10
49.50
29.50
33.90
11.03
10.95
11.05
98.20
93.20
96.90
54.10
34.10
38.60
10.55
10.45
10.57
101.00
96.10
99.70
58.90
38.70
43.20
10.26
10.17
10.26
103.70
98.65
102.35
63.30
43.60
48.10
10.18
10.11
10.20
sensible capacity (Btuh)
1.10 x cfm
)
lwb
total capacity (Btuh)
4.5 x cfm
15 TONS
62
191.2
164.9
11.35
176.9
157.3
12.47
162.7
149.7
13.47
148.4
142.0
14.53
134.2
134.2
15.54
7500
96.30
34.10
11.77
97.85
36.30
11.42
98.95
38.70
11.12
101.75
43.40
10.64
104.20
49.00
10.32
107.00
52.90
10.26

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents