FVR-C11S-EN Safety Instructions WARNING Read this operation manual carefully and famil- Improper operation may result in death iarize yourself with the operation of the inverter before installation, connection (wiring), opera- or serious injury. tion or maintenance and inspection of the de- vice.
Page 4
FVR-C11S-EN Compliance with UL/cUL standards [Applicable to products with UL/cUL mark] 1. [WARNING] Take care of electric shock. Be sure to turn the inverter off before starting work. CAUTION 2. [CAUTION] When the charge lamp is lit, the inverter is still charged at a dangerous voltage.
Page 5
FVR-C11S-EN Compliance with low voltage directive in 6. The inverter has to be installed in environ- EU [Applicable to products with TÜV ment of pollution degree 2. If the environ- mark] ment is pollution degree 3 or 4, the inverter has to be installed in a cabinet of IP54 or higher.
Page 6
FVR-C11S-EN Compliance with low voltage directive in EU [Continued] CAUTION Use of wires specified in Appendix C of EN 60204 is recommended. Molded case circuit Recommended wire size [mm breaker (MCCB) or earth leakage Nominal Input circuit Power circuit breaker applied single phase Output...
Page 7
FVR-C11S-EN Instructions on use CAUTION WARNING 1. Do not carry the device by holding just the surface cover. Inverter may be dropped causing injury. 1. This inverter is designed to drive a three- phase induction motor and is not usable for 2.
Page 8
FVR-C11S-EN Instructions on wiring CAUTION WARNING 1. Check that the number of phases and the rated voltage of this product correspond to the number of phases and voltage of the 1. When the inverter is connected to power, AC power supply. connect it via a line-protection molded case Otherwise fire could occur.
Page 9
FVR-C11S-EN Instructions on operation 5. Never touch the inverter terminals when energized even if it has stopped. Otherwise electric shock could occur. WARNING 6. Never touch the keys on the keypad panel with a pointed object such as a needle. Otherwise electric shock could occur.
Page 10
FVR-C11S-EN Instruction on maintenance/inspection, Instruction on disposal and replacement CAUTION WARNING Since this product contains lead solder, it must be treated as industrial waste when it is disposed of. Entrust it to a 1. Do not commence inspection work until at least five minutes after the power has been waste processing company when dis- turned off (OPEN).
Unpack and check the product as explained below. If you have any questions or problems with this product, please contact Inspections FUJI ELECTRIC Co., Ltd., or your local FUJI inverter distributor. 1) Check the ratings name plate to confirm that the delivered product is the ordered one.
FVR-C11S-EN 1-2 Appearance Surface cover Keypad panel Frequency setting POT (VR) (built-in POT) Ratings nameplate Heat sink Cooling fan (1.5 kW or more) Charge lamp CRG Control terminal block Main circuit terminal block Single-phase 200V[ G,L1/L,L2/N,P1,P(+)] Main circuit terminal block [P(+),N(-),U,V,W, G] 1 Before Using This Product...
FVR-C11S-EN 1-3 Handling the Product Remove the surface cover as explained below. 1) For FVR0.1 to 0.75C11S-7EN 2) For FVR1.5 to 2.2C11S-7EN Grasp the upper and lower parts of the cover Expand the lower part of the cover horizontal- with both hands and pull it to the front of the ly, lift the cover to the front, and then remove inverter.
FVR-C11S-EN 1-4 Carrying Always hold the main unit while carrying this product. If it is carried by the cover or parts and not the main unit, the product may be damaged or dropped. Force must not be applied to the inverter cover during carrying because it is made of plastic.
FVR-C11S-EN 2 Installation and Connection 2-1 Operating Install this product at a place satisfying the conditions listed in Table 2-1-1. Environment Item Specifications Place Indoor Ambient temperature -10 to +50 °C Ambient relative humidity 5 to 95%RH (No condensation allowed) Atmosphere The product must not be exposed to dust, direct sunlight, corrosive gas, inflammable gas, oil mist, vapor, or water drops.
FVR-C11S-EN 2-2 Installation Method 5. If two or more inverters need to be installed in the same device or control panel, they should be arranged horizontally to minimize the influ- 1. Tightly fasten the product in the upright posi- ence of heat between them. If two or more in- tion on a strong structure using four bolts verters must be installed vertically, place a (M4) with the characters FVR-C11 facing the...
FVR-C11S-EN WARNING CAUTION Do not allow foreign matter such as 1. Always connect the ground wire. lint, paper dust, small chips of wood or Otherwise electric shock and fire could metal, and dust to enter the inverter or occur. adhere to the heat sink. Otherwise, a disaster such as burning 2.
FVR-C11S-EN 2-3-2 Connecting the main circuit and ground terminals Symbol Name Explanation L1/L,L2/N Main power supply input Connects single-phase power (Single-phase 200V input). U, V, W Inverter output Connects 3-phase motor. P1, P(+) For connection of DC Connects input power- factor correcting DC reactor reactor (optional).
Page 19
FVR-C11S-EN 3) DC reactor connecting terminal [P1, P(+)] 4) Inverter grounding terminal [ G] Always ground the inverter grounding termi- 1. Use this terminal to connect a input power- nal [ G] for safety and noise reduction. factor correcting DC reactor (optional). Grounding of the metal frames of electric Remove the jumper connected in the fac- equipment has to be done in accordance with...
Connect the control circuit terminals according to the set functions. 1) Digital input terminal Figure 2-3-3 shows the circuit configuration. Use a reliable contact without poor contact for input. Example: FUJI control relay HH54PW FWD or others 4.7k +24 to +27VDC P24/CM...
Page 21
FVR-C11S-EN When SW7 is set at CM When SW7 is set at P24 When +24 to +27 VDC is supplied to When FWD is short-circuited to P24/CM and the FWD - P24/CM, pressing the key on the key on the keypad panel is pressed, for- keypad panel starts forward operation.
Page 22
FVR-C11S-EN *Note the following when wiring: 3) Shielding sheath connection Connect one end of the shielding sheath of a shielded or twisted-pair shielded wire to the 1) Surge absorber connection ground terminal as shown in Figure 2-3-6. Do When the exciting coil of the magnetic con- not connect the other end.
Page 23
FVR-C11S-EN 4) Control terminal arrangement, screw size, Screw size: M2.5 and tightening torque. Tightening torque: 0.4 Nm Figure 2-3-7 shows the control terminal block arrangement. 30A 30B 30C FM X1 Figure 2-3-7 Control terminal block arrangement 5) Remove the plate at the bottom of the surface cover before performing inverter control wir- ing and reinstall it after the wiring as shown in Figure 2-3-8.
Page 24
FVR-C11S-EN Classifi- Terminal Terminal name Remarks Detailed specifications cation symbol Used as power supply for frequency Power supply for setting device Ω variable resistor (POT: 1 to 5 k (+10VDC 10mADC max.) Frequency setting 0 to +10VDC/0 to 100%,0 to +5VDC/0 Analog Ω...
Page 25
FVR-C11S-EN Classifi- Terminal Terminal name Remarks Detailed specifications cation symbol PID control cancel with Hz/PID ON (Hz/PID) PID control cancel PID control with Hz/PID OFF Digital Operation based on command from input Link operation (LE) RS485 with LE ON selection Inverter single operation with LE OFF DC Power supply (SW7 set to P24) Switching of...
FVR-C11S-EN 2-3-4 Connection examples 1) Keypad panel operation When power-factor correcting DC reactor is used P(+) P(+) P(+) N(-) MCCB Single-phase L1/L 200V input series 200 to 240V L2/N 50/60Hz RESET FUNC STOP DATA Frequency setting POT (VR) +10VDC Analog monitor Pulse output 4.7k Alarm output for...
Page 27
FVR-C11S-EN 1) The RUN and STOP keys on the keypad pan- el can be used to start and stop the operation and the frequency setting POT (VR) can be used to set a frequency only by connecting the power supply and motor with functions set in the factory.
Page 28
FVR-C11S-EN 2) External operation (When external power supply is used) When power-factor correcting DC reactor is used P(+) MCCB P(+) P(+) N(-) Single-phase L1/L 200V input series 200 to 240V L2/N 50/60Hz RESET FUNC STOP DATA Frequency setting POT (VR) Analog +10VDC meter...
Page 29
FVR-C11S-EN 1) Use this connection to start, stop the opera- tion and set the frequency with external sig- nals. 0 to 10V DC can be set while function F01 is set to 1 and +4 to +20mA DC can be set while function F01 is set to 2.
Page 30
FVR-C11S-EN 3) External operation (When internal power supply is used) When power-factor correcting DC reactor is used P(+) P(+) P(+) N(-) Single-phase 200V input L1/L series 200 to 240V L2/N 50/60Hz RESET FUNC STOP DATA Frequency setting POT (VR) Analog +10VDC meter Frequency setting...
Page 31
FVR-C11S-EN 1) Use this connection to start, stop the opera- tion and set the frequency with external sig- nals. 0 to 10V DC can be set while function F01 is set to 1 and +4 to +20mA DC can be set while function F01 is set to 2.
Page 32
FVR-C11S-EN 4) Connection to PLC (When external thermal O/L relay is used) External thermal O/L relay MCCB P(+) P(+) N(-) Single-phase L1/L 200V input series 200 to 240V L2/N 50/60Hz To X3 terminal output terminal of PLC RESET FUNC STOP DATA Frequency setting POT (VR) Analog...
Page 33
FVR-C11S-EN 1) Set SW7 at CM. 2) In the figure above, the power is supplied to the external thermal relay from the power supply of the PLC. If the power supply of the PLC is turned off while the inverter remains turned on, OH2 trips.
Page 34
FVR-C11S-EN 5) Connection to PLC (When analog signal is input from PLC) P(+) P(+) N(-) External thermal relay MCCB Single-phase L1/L 200V input series L2/N 200 to 240V 50/60Hz To X3 terminal output terminal of PLC RESET FUNC STOP DATA Frequency setting POT (VR) Analog +10VDC...
FVR-C11S-EN 2-4 Others 2-4-3 Leakage current Leakage current flows through the inverter I-O 2-4-1 Harmonic component wiring and motor stray capacitance when the in- verter transistor is turned on and off. A harmonic component which may influence the Table 2-3-3 lists the countermeasures for the phase-advance capacitor and generator is in- problems caused by the leakage current.
FVR-C11S-EN 3 Operation 3-1 Inspection Check the following before operation: 1) Check whether the connection is correct. and Prepara- For single-phase 200V series, check whether the power supply is tion before connected correctly to the L1/L and L2/N terminals. Also check whether the inverter grounding terminal G is securely connected.
FVR-C11S-EN 3-3 Trial Run The motor rotates when a frequency value and running command are input from the keypad panel or external signal terminal. Refer to Table 3-3-1. Use a low frequency (about 5Hz) for trial runs. A frequency can be set using the built-in frequency setting POT (VR) , and forward/stop can be performed using the keypad panel with the functions set in the factory.
Page 38
FVR-C11S-EN Check the following items: a) Rotation direction b) Whether rotation is smooth (whether there is a motor buzzing noise or abnormal vi- bration) c) Whether acceleration and deceleration are smooth d) Whether the inverter cooling fan is rotating (1.5kW or more) If no abnormality is detected, check the item again by increasing the frequency.
FVR-C11S-EN 4 Keypad Panel 4-2 Operating Keypad Panel 1) Switching monitor 4-1 Names and Functions The display can be switched between fre- quency display and output current display by pressing the in Operation mode. 6 0. 0 1. 2 A Frequency Current 1) Frequency is displayed as a percentage with the least...
Page 40
FVR-C11S-EN 3) Changing frequency The frequency increases when the is pressed and decreases when the is pressed while function is set to F 0 1 The change speed is increased when the is pressed at the same time as the Note: Do not turn the power off for five seconds after monitor switch- ing or function setting, to prevent Er1 occurrence.
FVR-C11S-EN 5 Selecting Function 5-1 Function Selection List F: Fundamental functions Func- Change User tion Min. Factory during Name Setting range Unit set- code unit setting opera- ting tion 0: Data change enabled, Data protection 1: Data protected 0: Key operation ( key) 1: Voltage input (terminal [12]) (0 to +10VDC)
Page 42
Electronic 0: Inactive thermal overload 1: Active (for 4-pole standard motor) relay for motor 2: Active (for 4-pole FUJI inverter motor) (Select) Typical value of (Level) 20 to 135% of inverter rated current 0.01 FUJI 4-pole...
Page 43
FVR-C11S-EN Func- Change User tion Min. Factory during Name Setting range Unit set- code unit setting opera- ting tion Motor sound 0 to 15kHz (carrier freq.) 0.75kHz is set when 0 is specified 0: Level 0 1: Level 1 (sound tone ) 2: Level 2 3: Level 3 FM terminal...
Page 44
FVR-C11S-EN C: Control Functions of Frequency Func- Change User tion Min. Factory during Name Setting range Unit set- code unit setting opera- ting tion Jump frequency1 0 to 120Hz (Hysteresis) 0 to 30Hz Multistep frequency 1 0.0 to 120Hz P: Motor Parameters Func- Change User...
Page 45
FVR-C11S-EN Func- Change User tion Min. Factory during Name Setting range Unit set- code unit setting opera- ting tion 0: No retry Retry (count) 1: Retry (Count is fixed to 5.) Cooling fan on/ 0: Inactive off control 1: Active 0: Inactive PID control 1: Active (forward operation)
Page 46
FVR-C11S-EN Func- Change User tion Min. Factory during Name Setting range Unit set- code unit setting opera- ting tion 0: Er8 trip with eight continuous commu- nication errors or check sum errors 1: Er8 trip after the time (o03) set in the timer elapses with eight continuous Selection of communication errors or check sum...
FVR-C11S-EN 5-2 Details of Each Function Operation method Data protection Change during Factory setting operation Change during Factory setting operation The following four values can be selected: refer to Table 2-3-3. Set data can be locked to prevent it from being Key operation [ key] changed by mistake when using the keypad...
Page 48
FVR-C11S-EN External signal operation (Digital input) Maximum output frequency (FWD, REV) When the external power supply is Change during Factory setting used (Set SW7 at CM): operation Forward operation with +24 to +27 VDC supplied to FWD - P24/CM and decel- 50Hz eration to stop with them open.
Page 49
FVR-C11S-EN Base frequency Acceleration time Change during Change during Factory setting Factory setting operation operation 50Hz 6. 0s The time taken to increase from 0. 0 This function sets a base frequency (branch 0.0 Hz to the maximum output fre- point between constant torque characteristic quency can be set in an increment and constant output characteristic).
Page 50
Output frequency f in 0.01A step and values more than 10.0A can be set in 0.1A step. when using a FUJI inverter motor Set the value obtained by multiplying the motor (FV motor). rated current by coefficient K in the table below according to the wiring length between the in- verter and motor.
Page 51
FVR-C11S-EN Electronic thermal O/L relay The graph below shows the electronic thermal O/L relay operating characteristics. Output cur- (thermal time constant) rent values for the electronic thermal operating levels (values set with function F11) are plotted Change during horizontally and operating times for output cur- Factory setting operation rent are plotted vertically.
Page 52
FVR-C11S-EN Restart after momentary Frequency limiter (High) power failure (Select) Change during Factory setting operation Change during Factory setting operation 70Hz Frequency limiter (Low) This function determines whether operation is restarted upon recovery from momentary power failure: Change during Factory setting operation Inactive Failure while inverter is stopped:...
Page 53
FVR-C11S-EN Gain Bias frequency (for frequency setting signal) Change during Factory setting operation Change during Factory setting operation This function outputs a frequency biased for the analog frequency setting. This function outputs the frequency obtained by multiplying the reference frequency by a ratio. -1 2 0 This function selects an analog input signal level -120 to 120Hz can be set with...
Page 54
FVR-C11S-EN DC injection brake (Braking time) These functions set a starting or stop frequency in a range from 1 to 6Hz in 1Hz step. Change during Factory setting operation 0.0s This function sets the DC injection braking time. : No DC injection braking Output frequency in forward/reverse operation 0.1 to 30.0 : DC injection braking time 0.1 to 30s 0.2Hz...
Page 55
FVR-C11S-EN FM terminal (voltage adjust) Change during Factory setting operation Change during Factory setting operation 0. 0 100% Data cannot be changed. This function regulates the frequency meter volt- age level output to the FM terminal in the range from 0 to 200% (in 1% step). Motor sound (carrier freq.) (Full scale about 0VDC) Change during...
Page 56
FVR-C11S-EN FM terminal (Function) X1 terminal (function selection) X2 terminal Change during X3 terminal Factory setting operation Factory Change during setting operation This function selects the contents of output to the FM terminal. Output frequency (maximum output frequency = 100%) Output current Multistep frequency selection 1 (SS1) (inverter rated current x 2 = 100%)
Page 57
FVR-C11S-EN Coast-to-stop command (BX) Link operation selection (LE) Inverter output is cut when the BX ter- Operation setting can be done by com- minal is connected to the P24/CM ter- mands from RS485 when the LE termi- minal. nal is connected to the P24/CM OFF input is assumed when BX is not terminal.
Page 58
FVR-C11S-EN Multistep frequency 1 Multistep frequency 2 Jump frequency 1, 2, 3 Multistep frequency 3 Factory Change during Factory Change during setting operation setting operation 0.0Hz 0.0Hz 0.0Hz 0.0Hz 0.0Hz 0.0Hz These functions set a multistep frequency from 0 These functions jump frequencies to prevent to 120Hz in 0.1Hz step (for 99.9 Hz or less) or overlap between the load mechanical resonance 1Hz step (for 100Hz or more) by switching the...
Page 59
FVR-C11S-EN Operation time Trip history This function displays the integration time of This function memorizes the history of the last power supply applied to the inverter. four protection operations. 0 to 655 are displayed to indicate 0 to 65500 Each data item can be called using the key.
Page 60
FVR-C11S-EN Data initialization Cooling fan on/off control Change during Change during Factory setting Factory setting operation operation This function initializes data items set with all : ON-OFF No control (always on) functions to values set in the factory. Manually set value : ON-OFF Control (The fan is turned off when the inverter temperature becomes low after opera-...
Page 61
FVR-C11S-EN PID control PID control (D-gain) (Feedback signal select) Change during Factory setting operation Change during Factory setting operation 0.00s This function sets a derivative time. This function selects a PID control feedback sig- nal. 0. 0 0 : No derivative : Derivative time 0.01 to 0.
FVR-C11S-EN PID control In PID control, an output frequency is adjusted to a feedback value. F 0 1 to set a frequency and H 2 1 make the feedback value and the reference value equal. PID arithmetic unit Switching Deviation Inverter Reference between FWD...
FVR-C11S-EN 6 Protective Function 6-1 List of protec- When the protective function is activated, inverter output is instantly cut off (while the motor coasts until it is stopped), and an alarm is issued, tive functions and the details of the alarm are displayed on the keypad panel. Keypad Alarm Name panel...
Page 64
FVR-C11S-EN Keypad Alarm Name panel Contents of operation display If the control circuit terminal THR (functional change of X1 to X3 ter- External Alarm minals) is set to OFF, an alarm is issued and the inverter is tripped. If the motor current exceeds the operating level set by the electronic Motor thermal O/L relay, output is shut down to protect the motor, an alarm overload...
When the operation command is set to ON, check that operation starts after resetting. If the cause of tripping is Er1, reset the error and initialize data. If the inverter is not reset, contact Fuji Electric. 10ms or more Reset command...
Faulty invert- with load? er or error ’because of Has load changed noise. suddenly? Contact Fuji Electric. Acceleration Reduce time setting too torque boost short compared amount. with load? Can the Can the Prolong acceleration...
Page 67
Can the moment of inertia of load be Reduce moment reduced? of inertia. Reduce regenerat- Can regenerating load be reduced? ing load. DC injection brake Consider using DC used? injection brake. Review braking method. Contact Fuji Electric. 7 Troubleshooting...
Page 68
Probably faulty inverter or error because of noise, etc. Does LU activate when Contact Fuji Electric. circuit breaker or mag- Power transformer netic contractor capacity adequate? switched to ON? Probably faulty control...
Page 69
Probably faulty Is the alarm function of inverter or error be- the external device cause of noise. operating correctly? Contact Fuji Electric. Is electronic ther- Set to correct mal O/L relay set- level. ting correct? Remove the cause of alarm function activation.
Page 70
Turn power OFF then ON again after CHARGE lamp has gone out. Is data displayed Noise source Remedy faulty on LED? nearby? parts. Inverter is normal. Probably faulty Continue inverter. Contact operation. Fuji Electric. 7 Troubleshooting...
Page 71
[In case RS485 communication is not used Communication Error Er8 Probably faulty o00 is set to 1? inverter. Contact Fuji Electric. Set o00 to 0. For Er8 measures when using RS485, refer to the instruction manual for optional RS485 communication card. 7 Troubleshooting...
Is the operation method Possibly of faulty If no error is detected, the keypad panel or inverter. continue operation. input signal? Contact Fuji Electric. Keypad Input panel signal External wiring between Forward or reverse Does motor run if RUN...
Page 73
Inverter output terminals Probably faulty inverter. Defective motor. (U,V,W) supplied with Contact Fuji Electric. proper voltage? Load excessive? Motor wiring correct? Remedy wiring error. Load is excessive, re- sulting in motor lock.
Page 74
Replace faulty Setting of Probably faulty frequency setting acceleration/ inverter or error POT(VR) or signal deceleration time because of noise, etc. converter as excessively long? Contact Fuji Electric. appropriate. Change setting to correct acceleration/ deceleration time for load. 7 Troubleshooting...
Page 75
Motor stalls during acceleration Acceleration time Prolong time setting too short? setting. Moment of inertia Consult with of motor or load Fuji Electric. excessive? Special motor in use? Reduce moment of inertia of load or increase inverter capacity. Use thicker cable...
Page 76
Motor been continuously operated Use motor exclusive to at extremely low inverter. speed? Lighten load or in- Load excessive? crease motor capacity. Is the output voltage (at terminals U,V,W) Faulty motor. balanced? Probably faulty inverter. Contact Fuji Electric. 7-11 7 Troubleshooting...
Page 77
F00 or H03? simultaneously. Function to be changed F02? Open FWD and REV FWD or REV command. terminal connected to P24/CM terminal? Function to be changed Change other F05, F06, F24, H01 or functions. H02? Contact Fuji Electric. 7 Troubleshooting 7-12...
FVR-C11S-EN 8 Maintenance and Inspection WARNING Execute the daily inspection and periodic in- 1. Start inspection five minutes or more after spection for preventing a fault and ensuring turning off the power supply. (Check that long-term reliability. the charge lamp (CRG) goes off, and Note the following regarding the work.
Page 79
FVR-C11S-EN Check part Check item How to inspect Evaluation criteria 1. Check the ambient air tem- 1. Measure by visu- 1. The specified stand- perature, humidity, vibra- al inspection and ard value must be tion, atmosphere (dust, gas the meter. satisfied.
Page 80
FVR-C11S-EN Check part Check item How to inspect Evaluation criteria 1. Discoloration and distortion 1., 2. Visual 1., 2. Not abnormal. of a conductor by overheat- inspection Conductor ing? and wire 2. Cracks, crazing, and discol- oration of the wire sheath? Terminal Not damaged? Visual inspection...
Page 81
FVR-C11S-EN Check part Check item How to inspect Evaluation criteria 1. Loose screws or connec- 1. Tighten more. 1., 2., 3., 4. tors? Not abnormal. 2. Olfactory and 2. Unpleasant smell or visual inspection Control discoloration? 3., 4. Visual PC board 3.
FVR-C11S-EN 8-3 Electrical The indicated values depend on the meter types because of harmonic components included in the voltage and current of the main power sup- measure- ply (input) and the output (motor) side of the inverter. Therefore, when ments in the measuring with a meter for the commercial power frequency, use the meters shown in Table 8-3-1.
If the dielectric strength test must be conducted, contact your local distributor or nearest Fuji’s sales office. 1) Megger test for the main circuit 1. Test with a 500V DC megger.
Parts should be replaced as 2. The product is used outside the standard shown in Table 8-5-1. specified range. For spare parts, please contact Fuji distributor. 3. The cause is dropping after purchasing or damage during transport. Standard 4.
FVR-C11S-EN Item Specifications Braking torque Starting frequency: 3Hz (fixed), Braking current (0 to 100%), DC injection braking Braking time ( 0.0 to 30.0s) Protective structure Closed type IP20 (IEC60529) Cooling method Self-cooling Fan cooling Mass [kg] Notes: 1) A 4-pole standard motor is assumed as a nominal applied motor.
Page 87
FVR-C11S-EN Item Specifications Remarks Analog setting: 1.0% of maximum frequency (at 25 10°C) Accuracy Keypad panel setting: 0.01% of maximum frequency (at -10 to +50°C) Analog setting: 1/256 of Maximum frequency Setting resolution Keypad panel setting: 0.1Hz (99.9Hz or less), 1Hz (100Hz or more) Output voltage proportional to input voltage.
Page 88
FVR-C11S-EN Item Specifications Remarks High and low limits can be set for output frequency Frequency limiter between 0 to 100% in Hz The bias frequency can be set from -100 to +100% Bias frequency in Hz. Gain (frequency 5VDC or 10VDC gain can be selected. setting signal) Jump frequency (3 points) and jump hysteresis Frequency jump...
Page 89
FVR-C11S-EN Item Specifications Remarks [Cause of trip by code] OC1 (Overcurrent: during acceleration) OC2 (Overcurrent: during deceleration) (Overcurrent: while running at constant speed) OU1 (Overvoltage: during acceleration) OU2 (Overvoltage: during deceleration) (Overvoltage: while running at constant speed) Tripped LU (Undervoltage) OH1 (Overheating: Heat sink) OH2 (Overheating: External alarm) OL (Overload: Motor)
Page 90
Remarks Detects overcorrect due to ground fault on inverter Ground fault output side to protect inverter. (Detect at starting) Protect general-purpose motor or FUJI inverter Motor protection motor with electronic thermal overload. The inverter is protected against phase failure on...
Page 91
FVR-C11S-EN Item Specifications Remarks 3 mm: 2 to less than 9 Hz 9.8m/s : 9 to less than 20 Hz Vibration 2m/s : 20 to less than 55 Hz 1m/s : 55 to less than 200 Hz Storage temperature -25 to +65°C Storage humidity 5 to 95% RH (No condensation) Higher harmonics...
FVR-C11S-EN 9-4 Selection of It is recommended to use a prescribed wire according to the EN60204 Appendix C. Peripheral Device Molded case cir- Magnetic Recommended wire size (mm cuit breaker contactor (MC) (MCCB) Input circuit Input circuit Earth-leakage Output Single-phase Single-phase circuit breaker circuit...
FVR-C11S-EN 10 Options 10-1 Built-in There is an optional built-in card for RS485 serial communication. Ask at the inverter distributor for details. Options 10-2 External Options Molded case circuit The molded case circuit breaker (MCCB) is connected for protecting the breaker main circuit wiring to the inverter and for turning power on and off.
FVR-C11S-EN 12 Compliance with standards POWER INPUT FUSE (See instruction 12-1 UL/cUL standards manual for rating.) [Applicable to products with UL/cUL mark] L1/L L2/N P(+) 12-1-1 General The UL standards stand for Underwriters Labo- ratories Inc. and they are safety standards aim- ing at prevention of fire and other accidents in the United States, thereby providing protection [THR]...
FVR-C11S-EN 12-2 Compliance with EMC 12-3 Compliance with low voltage directive in EU [Applicable to directive in EU [Applicable to products with CE mark] products with TÜV or CE mark] 12-2-1 General 12-3-1 General The CE mark indicated on the FVR-C11S series concerns with European minister directorate di- The general purpose inverter is applicable for rective 89/336/EEC concerning the environmen-...
FVR Inverters con- ment on Council Directive 89/336/EEC, tain high-power semi-conductor devices which Fuji Electric Co., Ltd. has chosen to classify the are switched at high speeds to synthesize a FVR-C11S range of Inverters as "Complex near-sinusoidal current wave form across the Components".
Page 101
FVR-C11S-EN Max. Mount Applied Rated Dimensions Wiring Total Inverter Filter Type Rated Dims Y x X Fig. Inverter Current LxWxH [mm] L’ [mm] Weight [kg] Fixings Voltage [mm] FVR0.1C11S-7EN M4 x 12 Fig. EFL-0.2C11-7 180x86x38 155.5x60 Approx. 0.7 FVR0.2C11S-7EN 13-2-1 FVR0.4C11S-7EN M4 x 12 Fig.
FVR-C11S-EN 13-3 Recommended Installation 1. Use the correct filter according to Table 13-2-1. Instructions 2. Install the Inverter and filter in the electrically It is necessary that these instructions must be shielded metal wiring cabinet. followed to conformed to EMC Directive. 3.
Page 103
FVR-C11S-EN When power-factor correcting Metal Wiring DC reactor is used. Cabinet Power supply 1-phase 200 to 240V P(+) P(+) N(-) RFI Filter 50/60Hz Motor L1/L L2/N Frequency setting voltage input (0 to +10VDC) In case of motor power cable, fix a part of shield by a cramp.
Page 104
Solutions for Drives European headquarter Fuji Electric FA Europe GmbH Goethering 58 D-63067 Offenbach/Main Tel.: +49-69-66 90 29-0 Fax: +49-69-66 90 29-58 info_inverter@fujielectric.de http://www.fujielectric.de Germany Fuji Electric FA Europe GmbH Fuji Electric FA Europe GmbH Vertriebsgebiet South Vertriebsgebiet North Drosselweg 3 Friedrich-Ebert-Str.
Need help?
Do you have a question about the FVR-C11S-7EN Series and is the answer not in the manual?
Questions and answers