Cable Passage - Carrier 40KMC---N Installation Manual

Split system global cassette indoor unit
Hide thumbs Also See for 40KMC---N:
Table of Contents

Advertisement

40KMC---N
Electrical connections
Wiring diagram - Cooling only or heat pump units with electric heater
GB - 14
A/C COOLING ONLY
H/P HEAT PUMP
60Hz Special Exsport Market
NOTE:
THE ELECTRIC HEATER POWER
SUPPLY CABLE MUST BE OF THE 5G2.5
H07 RN-F TYPE.

Cable passage

LEGEND
FACTORY WIRING
FIELD WIRING
CONNECTOR
TERMINAL ON COMPONENT
TERMINAL ON STRIP
NORMALLY CLOSE CONTACT
NORMALLY OPEN CONTACT
CAPACITOR
SENSOR
TRANSFORMER
FC
FAN CAPACITOR
FS
SAFETY MICRO FLOAT
IFM
INDOOR FAN MOTOR
PS
DRAIN PUMP
T
TRANSFORMER
C1
LED/IR BOARD CONNECTOR
C2
FLOAT CONNECTOR
C3
FAN MOTOR CONNECTOR
C4
LOUVRE MOTOR CONNECTOR
C5
PUMP CONNECTOR
*
LM
LOUVRE MOTOR
*
MSL
MICROSWITCH LOUVRE
PCB
RELAY BOARD
ELECTRIC HEATER
HTR
ST
SAFETY THERMOSTAT
IF PRESENT
*
R-
LIVE POWER SUPPLY
C-
NEUTRAL POWER SUPPLY
WIRE COLOURS
A
O
BROWN
B
R
BLUE
C
BLACK
W
GREY
G
Y
YELLOW/GREEN
Y-G
IMPORTANT
THE WARRANTY WILL BE INVALIDATED,
IF FACTORY WIRING AND SETTINGS ARE
FIELD-CHANGED.
Power supply cable
Interconnection cable
Interconnection cable
Electric heaters power supply cable
(optional)
Room Controller/CZM connecting cable
(optional)
Refer to the control manual.
ORANGE
RED
WHITE
YELLOW

Advertisement

Table of Contents
loading