Power Supply And Connecting Cable Connection; Power Supply Input Wiring Diagram - Carrier 42GCVPH010-303P Installation Manual

Table of Contents

Advertisement

Connecting cable
Stripping length of the connecting cable
50 mm
10 mm
3
2
1
10 mm
70 mm
Power input at Outdoor Terminal Block
Indoor
Terminal
Block
Outdoor
Terminal
Block
CAUTION
1. The power supply must be same as the rated of air conditioner.
2. Prepare the power source for exclusive use with air conditioner.
3. Circuit breaker must be used for the power supply line of this air conditioner.
4. Be sure to comply power supply and connecting cable for size and wiring method.
5. Every wire must be connected firmly.
6. Perform wiring works so as to allow a general wiring capacity.
7. Wrong wiring connection may cause some electrical part burn out.
8. Incorrect or incomplete wiring is carried out, it will cause an ignition or smoke.
9. This product can be connected to main power supply.
Connection to fixed wiring : A switch which disconnects all poles and has a contact separation at least 3 mm must be incorporated in the fixed wiring.

Power Supply and Connecting Cable Connection

Power Supply Input at Outdoor Unit Terminal Block
Indoor Unit
Connecting cable connect to 1 2 3
Terminal block (1 2 3)
Earth line
Connecting cable
Earth line

Power Supply Input Wiring Diagram

Chassis
Chassis
Power input
Connecting cable
14
Outdoor Unit
1 2 3
L N
Earth line
Power supply cable
Earth line

Advertisement

Table of Contents
loading