Black Tube Connection; Red Tube Connection; 6" Final Filter Installation - Watts Premier 5 SV DELUXE Installation, Operation And Maintenance Manual

Reverse osmosis system
Table of Contents

Advertisement

Black Tube Connection

Note:
The tubing must be as SHORT and STRAIGHT as possible, making a downward slope from
faucet to drain saddle to allowfor proper drainage.
Step 24
Measure the black tube from faucet to the black drain
saddle and make a straight cut with a sharp knife
though tube.
Step 25
Remove black plastic nut from drain saddle. Slip black tube
through black nut. Insert black tube into the opening in the
drain saddle and tighten the black nut securely.
Note:
This is a gravity fed line, if there is any bend in the tube the
rinse water will not flow into the drain properly. Water will back
up and come out the air gap hole in the back of the faucet
base.

Red Tube Connection

Step 26
Using the white plastic union in the parts bag, determine where
the red tubing from the faucet and the black tubing from the RO
membrane housing would join together comfortably. Cut the
tubes leaving a straight cut on both tubes. Insert the red tube in
one end of the white plastic union and the black tube in the other
end. Use a 5/8" wrench to tighten both of the white plastic nuts
securely.

6" Final Filter Installation

Step 27
Gather the pieces needed for the Final Filter installation. Each
unit is supplied with a final filter and 2 white plastic connectors.
Step 28
Remove the blue caps from the final filter.
Page 10