Watts Premier RO-PURE Plus Installation, Operation And Maintenance Manual

Watts Premier RO-PURE Plus Installation, Operation And Maintenance Manual

Water supply

Advertisement

INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Please read carefully before proceeding with installation. Your failure to follow any attached instructions
Refer to enclosed warranty for operating parameters to ensure proper use with your water supply.
Watts Premier
Phone: 800-752-5582
Manual: 199519
or operating parameters may lead to the product's failure.
Save manual for future reference
Model: RO-PURE Plus
System Tested and certified by WQA against NSF/ANSI Standard
58 for the reduction of the claims specified on the performance
data sheet, and NSF/ANSI 372 for "Lead Free" compliance.
8716 W Ludlow Drive, Suite 1
www.premierH2o.com
Warning
Page 1
Peoria, AZ 85381
Fax: 623-866-5666
Manual Date: 07/20/2016

Advertisement

Table of Contents
loading

Summary of Contents for Watts Premier RO-PURE Plus

  • Page 1 Please read carefully before proceeding with installation. Your failure to follow any attached instructions or operating parameters may lead to the product’s failure. Save manual for future reference Model: RO-PURE Plus System Tested and certified by WQA against NSF/ANSI Standard 58 for the reduction of the claims specified on the performance data sheet, and NSF/ANSI 372 for “Lead Free”...
  • Page 2 Stage 4- VOC Block filter, recommend change 12 months. Premier RO-Pure Plus system conforms to NSF/ANSI 58 for VOC reduction. Through the specialty (VOC) like MTBE’s, Atrazine, Benzene, 2,4-D,Lindane and others from your drinking water. It is estimated that VOC’s are present in one-fifth of the nation’s water supplies.
  • Page 3: Table Of Contents

    ** Before installation, please take a moment to fill out the warranty card on page 23. Table of Contents Operational Parameters ........................4 Contents of Reverse Osmosis System .................... 4 Installation & Startup Tools Recommended For Installation ....................4 Plumbing diagram and parts list ...................... 5 Drill a Hole for the Reverse Osmosis Faucet ..................
  • Page 4: Operational Parameters

    Operational Parameters Installation must comply with State and local plumbing regulations. Do not use with water that is micro biologically unsafe or of unknown quality without adequate disinfection before or after the system. System is intended to be installed using the cold water supply only. Maximum 100°F (37.8°C) Minimum 40°F (4.4°C) Operating Temperatures:...
  • Page 5: Plumbing Diagram And Parts List

    Plumbing Diagram and Parts List FAUCET BLUE - 1/4” TUBE TANK BLACK - 3/8” TUBE DRAIN DRAIN SADDLE TANK AUTO SHUT-OFF VALVE ADAPT VALVE GREEN- 1/4” TUBE FEED COLD WATER Part No. Description ANGLE-STOP 115304 FILTER MODULE (SUPPLY) 134003 AUTOMATIC SHUT OFF VALVE 119007 STORAGE TANK - 3 GALLONS 560080 ADAPT-A-VALVE KIT 420102 FAUCET - TMT - BRUSHED NICKEL...
  • Page 6: Drill A Hole For The Reverse Osmosis Faucet

    Drill a Hole for the Reverse Osmosis Faucet Marble Counter-top We recommend contacting a qualified contractor for drilling a hole in a marble counter-top. Counter Top / Porcelain & Stainless Steel Sink Note: Most sinks are pre drilled with 1 ¼” diameter hole that you can use for your RO faucet. (If you are already using it for a sprayer or soap dispenser, see step 1) Porcelain sinks are extremely hard and can crack or chip easily.
  • Page 7: Faucet Installation

    Premier Monitored (Top Mount Twist) Faucet Installation Connect tubes to the RO faucet (Figure A) This RO faucet is equipped with quick connect fittings for easy tube installation. 1. In the parts bag, locate one 1/4” red tube, one 1/4” blue tube and one 3/8”...
  • Page 8: Adapt-A-Valve Installation

    Faucet Indicator Battery Replacement 1. Turn the handle on the storage tank ball valve to the “off” position and lower faucet handle to “on” position. 2. Remove the faucet handle cover at the slot - (A). Note: Water will dribble out of the spout, use caution when handling the electronic components.
  • Page 9: Drain Saddle Installation

    Drain Saddle Installation Drain Saddle fits standard 1 ¼” – 1 ½” drain pipes Caution: If you have a garbage disposal, do not install the drain saddle near it. Installation of the drain saddle must be either above the garbage disposal, or if a second sink drain is available, install it above the cross bar on the second drain.
  • Page 10: Blue Tube Connection

    Rear View of RO-Pure System Mounting Holes BLUE TUBE - TANK GREEN TUBE RED TUBE - BRINE BLUE TUBE - FAUCET VOC CARBON MEMBRANE PRE CARBON SEDIMENT Blue Tube Connection (From FAUCET To The RO Module) Locate the 1/4” BLUE tube from the RO faucet. Insert the open end of the tube with the 90* Step 13 bend into the open 1/4”...
  • Page 11: Green Tube Connection

    Green Tube Connection Locate green tube attached to the RO Module. Insert the open Green Tube Step 15 end of the green 1/4” tube into the open 1/4” quick connect fitting on the plastic water feed valve making sure the tube is pushed in all the way to the tube stop.
  • Page 12: Startup Instructions

    Congratulations! You have completed the installation of your new Reverse Osmosis system. Please Follow the Startup Instructions. Startup Instructions Turn on the incoming cold water at the angle stop valve and the Step 1 Adapt-a-Valve. Check the system for leaks and tighten any fittings as necessary.
  • Page 13: Changing The Filter Cartridges

    Changing The Filter Cartridges Your RO module is equipped with valve heads which will automatically turn off the water supply to each filter when the filter is released, thus you do not need to turn off the incoming water supply at the Adapt- a-Valve.
  • Page 14: Annual Sanitization

    Annual Sanitization Do not change your post-carbon filter until the sanitization has been completed. NOTICE The pre-filters and membrane can be changed before the sanitization Step 1: Turn off the water supply to your RO system at the adapt-a- valve and open the RO faucet to drain the storage tank. DOSING SYRINGE WITH NO NEEDLE NOTICE...
  • Page 15: Check Air Pressure In The Tank

    Check Air Pressure in the Tank NOTICE Check air pressure only when tank is empty of water! Check air pressure in the storage tank when you notice a decrease in available water from the RO sys- tem. Air can be added with a bicycle pump using the schrader valve that is located on the lower side of the tank behind the blue plastic cap.
  • Page 16: Troubleshooting

    TROUBLE SHOOTING Problem Cause Solution 1. Low/Slow Production Low Water Pressure Assure a minimum of 40 psi incoming water pressure. Premier sells a booster pump if home water pressure is low. Make sure water supply is turned on and feed water valve is all the way open.
  • Page 17: Product Technical & Warranty Information Performance Data Sheet

    Watts Premier 8716 W Ludlow Drive Suite #1 Peoria, AZ 85381 RO-Pure PLUS System conforms to NSF Standard 58 for specific claims. GENERAL USE CONDITIONS: 1. System to be used with municipal or well water sources treated and tested on regular basis to insure bacteriological safe quality. DO NOT use with water that is microbiologically unsafe or unknown quality without adequate disinfection before and after the system.
  • Page 18: Voc Performance Data Sheet

    VOC Performance Data Sheet Watts Premier 8716 W Ludlow Drive Suite #1 Peoria, AZ 85381 USA Influent Challenge Maximum Substance Percent Reduction Concentration Permissible Product Water Concentration (mg/L unless noted) ALACHLOR >98% 0.05 0.001 ATRAZINE >97% 0.003 BENZENE >99% 0.081 0.001...
  • Page 19: Arsenic Fact Sheet

    Arsenic Fact Sheet Arsenic (As) is a naturally occurring contaminant found in many ground waters. Arsenic in water has no color, taste or odor. It must be measured by an arsenic test kit or lab test. Public water utilities must have their water tested for arsenic. You can obtain the results from your water utility contained within your consumer confidence report.
  • Page 20 This page intentionally left blank Page 20...
  • Page 21: Service Record

    Service Record Model Number:__________ Serial Number:___________ Date of Purchase:__________ Date of Install:___________ Installed by:_____________ Sediment Carbon Membrane Date Filter Pre-Filter Post-Filter (6 months) (6 months) (2-5 years) (12months) NOTES: Page 21...
  • Page 22: Limited Warranty

    If any part of your Reverse Osmosis System is defective in workmanship (excluding replaceable filters and membranes), return unit after obtaining a return authorization (see below), less tank, within 1 year of original retail purchase, Watts Premier will repair or, at Watts Premier’s option, replace the system at no charge.

Table of Contents