Page 1
Warning Please read carefully before proceeding with installation. Your failure to follow any attached instructions or operating parameters may lead to the product’s failure and possible damage to property. Save manual for future reference Model: RO-PURE Available From: freshwatersystems .com...
Service Record Model Number:__________ Serial Number:___________ Date of Purchase:__________ Date of Install:___________ Installed by:_____________ Sediment Carbon Membrane Carbon Date Filter Pre-Filter (2-5 years) Post-Filter (6 months) (6 months) (6 months) NOTES: Page 2...
Watts Premier collects personal information when you register with Watts Premier. This information is stored in our data base and we do not rent, sell, or share personal information with other people or nonaffi liated companies.
Page 4
Thank you for your purchase of a state of the art Watts Premier Reverse Osmosis (RO) water treatment system. Water quality concerns are becoming more of a focus for the public. You may have heard about contaminants in the drinking water, such as Arsenic, Perchlorate, Chromium, Cryptosporidium or Giardia.
Thank you for your purchase of a Watts Premier Reverse Osmosis system. With proper installation and maintenance, this system will provide you with high quality water for years to come. All of Premier’s water enhancement products are rigorously tested by independent laboratories for safety and reliability. If you have any questions or concerns, please contact our customer service department at 1-800-752-5582 (outside USA 623-931-1977) or refer to our on-line troubleshooting at www.wattspremier.com.
Operational Parameters Installation needs to comply with state and local plumbing regulations. This system is intended to be installed on the cold water line only. Operating Temperatures: Maximum 100°F (37.8°C) Minimum 40°F 4.4°C) Operating Pressure: Maximum 85 psi (7.43 g/cm2) Minimum 40 psi (2.80 kg/cm2) Parameters:...
Note: Most sinks are predrilled with 1 ½” or 1 ¼” diameter hole that you can use for your RO faucet (If you are already using it for a sprayer or soap dispenser, you will need an additional hole for the faucet). Drill a Hole for the Faucet in a Porcelain Sink Porcelain sinks are extremely hard and can crack or chip easily.
Green Tube Connection (From RO Module to The Adapta Valve) Remove a brass nut, plastic sleeve and brass insert from the Step 11 parts bag. Place nut on the green tube (coming from the RO Module) fi rst, then the plastic sleeve (small taper end of plastic sleeve must point to the end of tube) and then insert the brass insert into the end of the tube.
Drain Saddle Installation - Part# 164016 Drain Saddle fi ts standard 1 ¼” – 1 ½” drain pipes Caution: If you have a garbage disposal, do not install the drain line near it. Installation of the drain line must be either above the disposal, or if a second sink drain is available, install it above the cross bar on the second sink.
How To Use the Quick Connect Fittings For Tubing Connections To make a connection, the tube is simply pushed into the fi tting. Place a piece of tape 1/2” from end of tube to indicate how far the tube should be inserted. The unique patented locking system holds the tube fi...
Blue Tube Connection (From The RO Module To TANK) Step 22 Position tank in desired location. Stand it upright or lay it on its side (using the black plastic stand). Measure the blue tube (marked “TANK”) from the RO module over to the tank and cut it to length leaving a straight edge on the end of the tube.
Step 4 An optional ice maker kit (not included) may be purchased from Watts Premier by calling 1-800-752-5582 or buy on-line at www.wattspremier.com. If system is connected to an ice maker, turn the ice maker off (or do not allow water to fl ow to the ice maker) until Step 3 fl...
A water sample may be sent into Premier for a free test or a TDS (total dissolved solids) monitor can be purchased from Watts Premier to test the incoming and reverse osmosis water. Membranes should be replaced when TDS reduction is 80% or less.
Check Air Pressure in the Tank Note: Check air pressure only when tank is empty of water! Check air pressure in the tank when you notice a decrease in available water from the RO system. Step 1 It is recommended that you drain the tank of water, and then pump up the RO tank in order to ensure all water is out of the tank.
TROUBLE SHOOTING Problem Cause Solution 1. Low/Slow Production Low Water Pressure Assure a minimum of 40 psi incoming water pressure. Premier sells a booster pump if home water pressure is low. Maker sure water supply is turned on and Adapta Valve is all the way open Crimps in tubing Check tubing and straighten or replace as necessary.
2. This system is acceptable for treatment of infl uent concentrations of no more than 27 mg/L nitrate and 3 mg/L nitrite in combination measured as N and is certifi ed for nitrite/nitrate reduction only for water supplies with a pressure of 280 kPa (40 psig) or greater. If your water supply is under 40 psi Watts Premier recomends the use of a RO booster pump for proper operation.
fi eld testing on our reverse osmosis units to determine trivalent arsenic reduction capabilities. Based upon Watts Premier fi eld testing, it has been determined that the RO units are capable of reducing up to 67% of trivalent arsenic from the drinking water.
Other Products from Watts Premier Watts Premier has other fi ne water fi ltration products and accessories to enhance your water and to compliment your existing RO System. Listed on the next several pages are only a few of the items we offer.
Page 20
Watts Premier Ice Maker Kit - High effi ciency replaceable fi lter that can last up to 5 years or 20,000 gallons. Prefect for residential and commercial ice makers as well as refrigerators, drinking fountains, coffee & tea brewers, motor homes and campers.
Page 21
Removing chlorine from your shower Special Chlorgon & KDF media – More effective then carbon medias with hot water applications in the removal of the following. √ Iron oxide (rust water) √ Free Chlorine (CL-) √ Dirt, sediment √ Combined Chlorine (Sodium Hypochlorite) √...
fi lters and membranes), return unit after obtaining a return authorization (see below), less tank, within 3 years of original retail purchase, WATTS PREMIER will repair or, at WATTS PREMIER’S option, replace the system at no charge. How to obtain Warranty Service: For warranty service, call 1-800-752-5582 for documentation and a return authorization number.