ERROR CODES:

When power is applied, the unit will automatically enter "reset/test" mode. This mode brings all the internal motors
to a home position. If there is an internal problem with one or more of the motors an error code will flash in the
display in the form of "XXer" were as XX will represent a function number. For example, when the display shows
"05Er," it means there is some type of error with the channel 5 motor. If there are multiple errors during the
start-up process they will all flash in the display. For example: if the fixtures has errors on channel 1, channel 1, and
channel 1 all at the same time, you will see the error message "01Er", "02Er," and "03Er" flash repeated 5 times.
If an error does occur during the initial start-upprocedure the fixture will self-generate a second reset signal and try
to realign all the motors and correct the errors, if the error persist after a second attempt a third attempt will be
made.
If after a third attempt all the errors have not been corrected the fixture will make the following determinations:
1) 3 or more errors - The fixture cannot function properly with three or more errors therefore the fixture will place
itself in a stand-by mode until subsequent repairs can be made.
2) Less than 3 errors - The fixture has less than 3 errors, therefore most other functions will work properly. The
fixture will attempt to operate normally until the errors can be correct by a technician. The errors in question
will remain flashing in the display as a reminder of internal errors.
pan movement-wheel error:
01 Er
The pan movement wheel is not located in the default position after start-upor after a reset command. This
message will appear after a fixture reset if the pan movement wheel's magnetic-indexing circuit malfunctions
(sensor failed or magnet is missing) or there is a stepper motor failure (defective motor or a defective motor IC
drive on the main PCB).

CLEANING AND MAINTENANCE

The following points have to be considered during the inspection:
1) All screws for installing the devices or parts of the device have to be tightly connected and must
not be corroded.
2) There must not be any deformations on the housing, color lenses, fixations and installation spots
(ceiling, suspension, trussing).
1) Mechanically moved parts must not show any traces of wearing and must not rotate with
unbalances.
2) The electric power supply cables must not show any damage, material fatigue or sediments.
Further instructions depending on the installation spot and usage have to be adhered by a skilled
installer and any safety problems have to be removed.
Disconnect from mains before starting maintenance operation.
We recommend a frequent cleaning of the device. Please use a moist, lint- free cloth. Never use
alcohol or solvents.
There are no serviceable parts inside the device except for the lamp. Please refer to the
instructions under "Installation instructions".
Should you need any spare parts, please order genuine parts from your local dealer.
CAUTION
- £ ± £ ´
-