Four winns Vista 328 Owner's Manual page 48

Four winns boat
Hide thumbs Also See for Vista 328:
Table of Contents

Advertisement

read the manufacturer’s literature included with the
owner’s packet for information regarding operation and
maintenance.
1. Control Functions
The HDR 600 uses a blacklit 7-segment display in con-
junction with a 3-button keypad to control all user func-
tions. At initial power up, the unit will begin normal op-
eration and display the digital depth and the units of
measure. Figure E5 shows a typical view you might
see on-screen at initial power-up.
Figure E5: Depthsounder (HDR 600)
The HDR600 uses 3 buttons to control the Shallow Alarm,
Deep Alarm, Keel Offset and Units of Measure function.
While in normal operation, pressing the SET button se-
lects a function and blinks its corresponding indicator
on the display. Once a function has been selected it
may be adjusted by pressing the UP and DOWN arrow
buttons to adjust the setting. Further presses of the
SET button will sequentially select the other functions
for adjustment. All user settings are remembered by
the HDR600, even when powered off.
When in the active function, a single press to an arrow
button will result in a single incremental adjustment.
Pressing and holding an arrow button will sequence
through a range of adjustments. If no adjustment is
made in 5 seconds, the unit will return to normal opera-
tion.
2. Shallow Alarm
The SHALLOW ALARM function can be set for depths
ranging from 1 to 20 feet and sounds an alarm when the
depth is less than the setting. See Figure E6.
Figure E6: Shallow Alarm
298/328 Vista Owner’s Manual
09/00
From normal operation, pressing SET once will display
the SHALLOW ALARM setting and blink the “SHAL-
LOW” icon. The UP ARROW will activate the SHAL-
LOW ALARM and also increase the selected value. The
DOWN ARROW will reduce the value. Hold the UP
ARROW until you reach the desired depth setting. See
Figure E7.
Figure E7: Shallow Alarm Setting Value
NOTICE
The maximum SHALLOW ALARM setting can
not meet or exceed the current DEEP ALARM
setting.
After your selection is made, the unit will return to nor-
mal operation after 5 seconds. The “SHALLOW” icon
should now be visible. See Figure E8.
Figure E8: “SHALLOW” Icon
If the depth of the water is less than the selected value,
the alarm will sound and the “SHALLOW” icon will blink
to indicate the alarm. Pressing any button will mute the
alarm; pressing SET will mute the alarm and activate
the SHALLOW ALARM function for additional adjust-
ment. To permanently turn off, use the DOWN ARROW
to return the display to “OFF”.
3. Deep Alarm
The DEEP ALARM can be set for depths up to 99 feet
and sounds an alarm when the depth is greater than the
setting.
Press SET until the DEEP ALARM function becomes
active. This is indicated by the blinking “DEEP” icon.
The UP ARROW will activate the DEEP ALARM and
also increase the selected value. The DOWN ARROW
will reduce the value. Continue to press and hold the
UP ARROW until you reach your desired value. See
Figure E9.
Section E
Page 8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vista 298

Table of Contents