Operating Instructions; Changing Programmed Data - Continental Girbau DL2X30CG Series Operator's Manual

Table of Contents

Advertisement

1. Load clothes into either the upper or lower drum (or both). Close the door(s) completely.
2. Deposit coin or coins equal to or greater than the displayed vend price. Upon deposit of the first coin, the green
light will flash on and off. This light will continue to flash, while additional money may be deposited, until either
the upper drum or lower drum is selected.
3. Select drying temperature by pressing the appropriate switch for the drum to be used. This will put out the green
flashing light, turn on the red light showing the selected temperature and display the amount of time purchased.
4. Press start switch to start drum.
ON RUNNING DRYER
-Opening the door will stop the drum. The drum will restart, if time has not expired, upon closing the door and
pressing the start switch.
-Selected temperature may be changed at any time.
-Running time may be extended by depositing money and pressing the temperature or start switch for the correct
drum. Unless time has expired, the controller will accept coins whether or not the original vend price is equaled.
If time has run out the dryer must be restarted as it was at the beginning of drying the load which requires meeting
or exceeding the vend price.
All operating parameters (vend price, temperature, cool-down times) are adjustable. Hours run and money count
information can be displayed and these registers are resettable to zero. There are seventeen programming steps.
These seventeen steps are:
STEP
DESCRIPTION
00
Lower Drum Hour Meter
01
Upper Drum Hour Meter
02
Left Coin Audit
03
Right Coin Audit
04
Hot Dry Temperature (Regular)
05
Medium Dry Temperature (Permanent Press) 120-170°F/45-75°C
06
Warm Dry Temperature (Delicates)
07
Left Coin Value
08
Right Coin Value
09
Vend Price
10
Time Per Coin
11
Time Per Right Coin
12
Free Vend Time
13
Hot Dry Cool Down Time
14
Medium Dry Cool Down Time
15
Warm Dry Cool Down Time
16
Temperature Scale

OPERATING INSTRUCTIONS

CHANGING PROGRAMMED DATA

RANGE
0-9999 Hours
0-9999 Hours
0-9999 Coins
0-9999 Coins
150-190°F/63-87°C
110-150°F/39-63°C
0-100 cents
0-100 cents
0-100 cents
0-99:55
0-99:55
Min:Sec
0-99:55
Min:Sec
0-10:00
Min:Sec
0-10:00
Min:Sec
0-10:00
Min:Sec
°F - °C
PROGRAMMING
INCREMENTS
----
----
----
----
5°F/3°C
5°F/3°C
5°F/3°C
5 sec.
5 Sec.
5 Sec.
5 Sec
5 Sec
5 Sec
ORIGINAL
SETTING
0
0
0
0
175°F/78°C
150°F/63°C
125°F/48°C
10¢
25¢
25¢
3:20
10:00
10:00
2:00
2:00
2:00
°F
9

Advertisement

Table of Contents
loading

Table of Contents