NOTE: Procedures and techniques that are considered important enough to emphasize. CAUTION: Procedures and techniques which, if not carefully followed, will result in damage to the equipment. WARNING: Procedures and techniques which, if not carefully followed, will expose the user to the risk of fire, serious injury, or death. www.dimplex.com...
OPERATION Figure 2 Figure 1 again. On Screen Display D & E . Thermostat Controls Adjusts the temperature set point to your individual require- The unit can be controlled by either the manual controls ments. Once the desired set temperature is reached the which are located on the upper right of the fireplace or the heater will turn off.
Compact Fireplace Surface Cleaning Use warm water only to clean painted surfaces of the Compact Fireplace. Do not use abrasive cleaners. Servicing Except for light bulb replacement and cleaning described above, an authorized service representative should perform any other servicing. www.dimplex.com...
SWITCHBOARD REPLACEMENT RELAY BOARD REPLACEMENT Tools Required: Phillips Head Screwdriver Tools Required: Phillips Head Screwdriver Flat Head Screwdriver Flat Head Screwdriver Needle Nose Pliers CAUTION: If unit was operating prior to servicing allow at least 10 minutes for lights, heating elements and top CAUTION: If unit was operating prior to servicing allow panel to cool off to avoid accidental burning of skin.
POWER CORD REPLACEMENT FLICKER MOTOR & FLICKER ROD REPLACEMENT Tools Required: Phillips Head Screwdriver CAUTION: If unit was operating prior to servicing allow Tools Required: Phillips Head Screwdriver at least 10 minutes for lights, heating elements and top CAUTION: If unit was operating prior to servicing allow panel to cool off to avoid accidental burning of skin.
Side Section 5. Gently open the bottom panel, laying it on the work sur- Edge face so that all of the components can easily be seen. (Figure 8) 6. Locate the LED lights along the back. Each light is www.dimplex.com...
TROUBLESHOOTING GUIDE PROBLEM CAUSE SOLUTION PART NUMBER General Circuit breaker trips or fuse Short in unit wiring. Trace wiring in unit. blows when unit is turned Improper circuit current rating Additional appliances may exceed the current rating of the circuit breaker or fuse. Plug unit into another outlet or install unit on a dedi- cated 15 amp circuit.
Page 12
Grinding or excessive noise Flicker rod hitting or rubbing Ensure rod is straight and mounted properly with the heater off against internal components in the bracket, spinning freely away from other components. Replace if necessary. Defective Flicker Motor Replace Flicker Motor 2000220100RP www.dimplex.com...
Need help?
Do you have a question about the DF2624L and is the answer not in the manual?
Questions and answers