General notes
Clearances
Your installer will have provided adequate space around the appli-
ance for safety and servicing access. Do not restrict this space
with the addition of cupboards, shelves etc. next to the appliance.
Left-hand side
Right-hand side
In Front
Above Casing (Vert. Flue)
Above Flue Turret
Below
Table 1
Room thermostat
A room temperature controller is may be fitted to control the cen-
tral heating. Refer to the instructions supplied with the thermostat
for information on siting and setting.
Cylinder thermostat - System boilers
The cylinder thermostat should be set to 60°C which will be sat-
isfactory for bathing/washing in normal circumstances.
Thermostatic radiator valves
It is recommended that this type of valve is fitted to all the radiators
except one, usually the radiator where the room temperature con-
troller is fitted. They should conform to the requirements of
BS2767:10.
Showers, bidets, taps and mixing valves – Combination
Boilers
Standard hot and cold taps and mixing valves must be suitable for
operating at mains pressure. Thermostatically controlled or pres-
sure equalising shower valves will guard against the flow of water
at too high a temperature.
Hot and cold mains fed water can be supplied directly to an over-
rim flushing bidet subject to local water company requirements.
8
10 mm
10 mm
600 mm
75 mm
30 mm
200 mm
6 720 610 604 GB (03.06)