Startup/Operation - STA-RITE CRISTAL-FLO T-150BP-1 Owner's Manual

High rate sand filters
Hide thumbs Also See for CRISTAL-FLO T-150BP-1:
Table of Contents

Advertisement

Aquatools
.WATERFORD, WI.
. Install O-Ring
on valve flange.
Install valve on tank.
Tank flange must
be clean; insert
collector pipe
into bottom
of valve.
Fig. 6
ort labeled
Aquatools
.WATERFORD, WI.
PUMP" should
53185
USA
oint toward
ump.
1/4" Max.
Install clamp
If unable to
and tighten
close gap
until clamp
to 1/4" or less,
ends (under
wait 15-30
bolt) are 1/4"
minutes and
apart.
retighten.
Fig. 7
Valve Setting
Purpose/Flow
FILTER
Normal filtration and
vacuuming; water goes
through filter to pool.
RINSE
For initial startup cleaning
and sand bed leveling
after backwash; water goes
through filter to waste.
RECIRCULATE
Circulates pool water;
bypasses filter.
Fig. 8
Startup/Operation (See Figure 9)
53185
USA
vere or fatal injury, filter system pressure must not exceed 50 PSI (345
kPa) under any circumstances. NEVER test this filter system with com-
pressed air; never operate system with water temperature above 95° F
(35° C).
pump OFF before changing valve position.
NOTICE: Do not add chemicals directly into the pool skimmer. Adding
undiluted chemicals may damage equipment and void warranty.
1. Open system valves and make sure pump is filled with water. Make
2. With pump OFF, set valve to 'BACKWASH' position.
3. Start pump, circulating water backwards through filter to waste.
4. Backwash until water runs clear (3-5 minutes).
5. Stop pump; set valve to 'RINSE' position.
6. Start pump; run pump for one minute.
7. Stop pump; set valve to 'FILTER' position.
Tap around
clamp while
8. Filter is now ready for service.
tightening to
help seat
9. Record clean starting filter pressure gauge reading as a reference.
clamp.
10. When pool is first filled, backwash once a day until pool water is
736 0294
Valve Setting
737 029
Hazardous pressure. To avoid explosion and possible se-
To prevent equipment damage and possible injury, turn
sure pool water level is 2" (51mm) above bottom of skimmer open-
ing.
NOTICE: To prevent pump from running dry, be sure water level
never drops below bottom of skimmer inlet. Add water to pool if
necessary to keep skimmer flooded while backwashing and rinsing.
sparkling clear. After that, backwash when pressure gauge shows 5 to
7 PSI (34.5 to 48 kPa) higher than starting pressure.
Valve Setting
Purpose/Flow
BACKWASH
Reverses flow for
cleaning; water
goes through filter
to waste.
CLOSED
Shuts off all flow to
filter and pool.
WINTERIZE
Leaves all valve ports
partially open for
winter storage.
738 029
7
Purpose/Flow
WASTE
Lowers pool level or
drains pool; water
bypasses filter,
goes to waste.
743 0294
g
Fig. 9: Valve settings for startup. Stop
pump before changing valve position.