56
en | Configuration
After completing setup, click <Save> to save your settings and go back to the previous menu.
2013.05 | 1.0 | DIVAR 3000/5000 Digital Video
Recorder
for another 10 seconds while the screen prompt, alarm upload, email will not be
activated again. After 10 seconds, the anti-dither time is over and the system can
generate an alarm if it detects another alarm signal.
Alarm out: If an alarm occurred, the system will enable a peripheral alarm device
connected to any of the selected outputs (default is output 1).
Latch: When the anti-dither time is ended, the channel alarm you selected in the alarm
output will continue for this period. The value ranges from 1 to 300 seconds (default is
10). This function is not for other alarm activation operations. The latch is still valid even
if you disable the alarm event function directly. When detection is complete, the system
automatically delays detecting again for this specified 'Latch' time
Show message: Select to display an alarm message in the local host screen.
Alarm upload: Select to upload the alarm signal to the network (including the central
alarm point).
Send email: Select to send an email if an alarm occurs.
Record channel: Select the appropriate channel(s) to record alarm video. You first need
to do the following:
First set the alarm record mode as 'Scheduled' in the Record interface (Main Menu >
Advanced > Record). Please note the manual record has the highest priority. If you
select Manual mode, the system will record continuously no matter if there is an
alarm or not.
Now go to the Schedule interface (Main Menu > Setting > Schedule) to set the
record type, corresponding channel number, week and date.
Select the record type: Regular/MD/Alarm/MD&Alarm. Please note: you cannot
simultaneously select MD&Alarm and MD (or Alarm).
Now go to the Encode interface to select the alarm record and set the encode
parameter (Main Menu > Setting > Encode).
Finally, set the alarm input as the local alarm and then select the record channel. The
select channel begins alarm record when an alarm occurred. Please note: the system
begins the alarm record instead of the MD record if the local alarm and MD event
occurred simultaneously.
PTZ activation: When an alarm occurs, the system can activate the PTZ operation. See
PTZ activation, page 61.
Delay: The delay time before PTZ activation is started. The value ranges from 10 to 300
seconds (default is 10).
Tour: Select to enable the tour function when an alarm occurs. The system supports only
one-window tour. See Display, page 63 for how to setup the tour interval.
Snapshot: Enable this function to snapshoot an image from the chosen camera(s) when
an alarm occurs. For snapshot operation, see Encode, page 39.
Sequence Mon. B: Check the box to enable this function. The Monitor B output can
display the alarm video of the current channel when there is an alarm signal.
Buzzer: Select here to activate the buzzer when an alarm occurs.