Operation - STA-RITE D Series Owner's Manual

Centrifugal pumps with trap for swimming pool use
Hide thumbs Also See for D Series:
Table of Contents

Advertisement

TABLE I – ELECTRICAL DATA - FUSING AND WIRING REQUIREMENTS
Model
DMH-171, DHH-169
DM2H-110, DH2H-112
DM2H3-110, DH2H3-112
DMH3-171, DHH3-169
DMJ-111, DHJ-113
DM2J-111, DH2J-113
DM2J3-114, DH2J3-113
DMJ3-111, DHJ3-113
NOTICE: Before using pump, check your motor nameplate for voltage. Your
electric supply voltage and the stamped nameplate voltage must agree.
Motors stamped 200 volts only or 230 volts only, must be used with that volt-
age only. Motors stamped with two voltages (for example 230/460 volts), may
be used with either supply voltage. For these motors check connections
against wiring diagram on motor nameplate and make any changes necessary
to agree with your supply voltage. If in doubt, call a licensed electrician.
Incorrect voltage will cause serious damage to the motor.
Some models are equipped with three phase motors. Three phase motors re-
quire magnetic starters.
To check motors for proper rotation: Remove the motor end cover. This ex-
poses the motor shaft. If hook-up is correct, the shaft will rotate clockwise.
Three Phase: If rotation is not clockwise, reverse any two leads to the starter.
The rotation will now be correct.
Single Phase: See wiring diagram on motor nameplate. BE SURE power is off
to the motor when working on electrical connections.
will be too hot to touch. Before handling pump or motor, stop motor and
allow it to cool for 20 minutes.
Motor
Voltage/
Max Load
HP
Hz/Phase
Amps
3
230/60/1
13.4
3
200/60/1
17.2
3
200/60/3
3
230/460/60/3
8.6/4.3
5
230/60/1
22.0
5
200/60/1
26.4
5
200/60/3
13.8
5
230/460/60/3
13.2/6.6
OPERA TION
Hazardous
suction.
boil water in pump body, and can cause severe burns to people working on
pump.
To reduce the risk of fire, do not allow leaves, debris, or foreign matter to col-
lect around the pump motor. To avoid burns when handling the motor, let it
cool for 20 minutes before trying to work on it. An automatic internal cutoff
Burn Hazard. Motor normally operates at high temperature and
Branch Fuse
Rating Amps*
20
25
8.4
15
15/15
14(2)/14(2)
30
40
20
20/15
12(3)/14(2)
Hazardous suction. Can trap hair or body parts, causing severe
injury or death by drowning. Do not block pump or strainer
suction with body. Small children using pool must ALWAYS
have close adult supervision!
Do not run pump against closed discharge valve. To do so can
Fire and burn hazard. Modern motors run at high temperatures.
8
Serv. to Motor - Dist. in Ft. (M)
0-100'
101-200'
(0-30M)
(30-60M)
12(3)
12(3)
10(5.5)
10(5.5)
14(2)
14(2)
14(2)/14(2)
10(5.5)
10(5.5)
8(8.4)
8(8.4)
12(3)
12(3)
12(3)/14(2)
201-300'
(60-90M)
10(5.5)
10(5.5)
14(2)
14(2)/14(2)
8(8.4)
8(8.4)
12(3)
12(3)/14(2)