Problem Solving
Check
g
Is the Aspect Ratio
set correctly?
Has condensation formed on the lens?

Interference or Distortion Appear in Images

Check
Is the image signal format setting correct?
(Only when projecting images from a video source)
Are the cables connected correctly?
Is an extension cable being used?
Is the correct resolution selected?
(Only when projecting computer images)
g
g
Are the Sync.
and Tracking
settings adjusted correctly?
(Only when projecting computer images)
Is the Resolution set to anything other than Auto?
(Only when projecting on a split screen)
Is Transfer layered window selected?
(Only when projecting USB Display)
You can change the Aspect Ratio of the projected image to suit the type, the ratio of height and width, and the resolution
of the input signals.
s "Changing the Aspect Ratio of the Projected Image"
If the projector is suddenly taken from a cold environment to a warm environment, or if sudden ambient temperature
changes occur, condensation may form on the surface of the lens, and this may cause the images to appear fuzzy. Set the
projector up in the room about one hour before it is used. If condensation forms on the lens, turn the projector off and
wait for the condensation to disappear.
Change the setting according to the signal for the connected equipment.
s Signal - Video Signal
p.176
Check that all the cables required for projection are securely connected.
s "Connecting Equipment"
p.33
If an extension cable is used, electrical interference may affect the signals. Use the cables supplied with the projector to
check if the cables you are using may be causing the problem.
Set the computer so that the signals being output are compatible with the projector.
s "Supported Monitor Displays"
p.245
s Computer's documentation
Press the [Auto] button on the remote control or the [
If the images are not adjusted correctly even after performing automatic adjustment, you can also make adjustments
from the Configuration menu.
s Signal - Tracking, Sync.
p.176
The image may be collapsed if the Resolution on the Configuration menu and the resolution of the projected image are
not the same.
If the image is collapsed, set the Resolution to Auto.
s Signal - Resolution
p.176
Click All Programs - EPSON Projector - Epson USB Display - Epson USB Display Vx.xx Settings, and then clear the
Transfer layered window checkbox.
Remedy
p.68
Remedy
] button on the control panel to perform automatic adjustment.