Important Safety Instructions

!
1. Read and follow all warning notices and instructions marked on the product or
included in the manual.
2. All installation and service must be performed by qualified service personnel, as
opening or removing covers may expose dangerous voltage points or other risks.
3. This product is intended to be used in a restricted access location. Connect the
product to a – 48 VDC SELV (Safety Extra Low Voltage) supply source that is
electronically isolated from the AC source. The – 48 VDC source is to be reliably
connected to earth. Connect the earthing (grounding) conductor to the protective
earthing (grounding) lug connector, identified by the protective earth symbol. This
is a safety feature. Equipment grounding is vital to ensure safe operation.
Prior to installation, use a voltmeter/ohmmeter to check the wiring for the presence
of earth ground. If the wiring is not properly grounded, the installation must not
continue until a qualified electrician has corrected the problem.
A readily accessible disconnect device as part of the building installation shall be
incorporated into the fixed wiring. The disconnect device (a – 48 VDC, 15 or 20A
circuit breaker or switch) must be included in the ungrounded supply conductor.
Overcurrent protection must be a 15 or 20A, – 48 VDC fuse or circuit breaker.
This product is to be installed only in a Restricted Access Location (dedicated
equipment rooms, equipment closets, or the like) in accordance with articles
110-16, 110-17 and 110-18 of the National Electrical Code, ANSI/NFPA 70, and
articles 2-308, 2-310, 2-312, 2-314, 2-200, and 2-202 of the Canadian Electrical
Code.
The rear I/O panel has provision for a permanently connected protective earthing
(grounding) conductor. Connect a 6 –14 AWG conductor to this solderless lug
connector, identified by the protective earth symbol.
4. Slots and openings in the cabinet are provided for ventilation. To ensure reliable
operation of the product and to protect it from overheating, these slots and
openings must not be blocked or covered.
5. Do not allow anything to rest on the power cord and do not locate the product
where persons will walk on the power cord.
6. Do not attempt to service this product yourself, as opening or removing covers
may expose you to dangerous high voltage points or other risks. Refer all servicing
to qualified service personnel.
7. General purpose cables are provided with this product. A UL Listed/CSA Certified,
minimum No. 26 AWG, telecommunications cable is provided for connection to the
network. Use this cable to reduce the risk of fire.
Special cables, which may be required by the regulatory inspection authority for
the installation site, are the responsibility of the customer.