2.2 Installation of the Hybrid IP-PBX
2.2.4

Installing/Replacing the Power Supply Unit

Function
PSU Type
PSU-S
(for KX-TDA100)
PSU-M
(for KX-TDA100/200)
PSU-L
(for KX-TDA200)
Power Switch
Ground Terminal
AC Inlet
Accessory and User-supplied Items
Accessory (included): Screws × 4, AC power cord × 1
User-supplied (not included): grounding wire
Note
For details about frame ground connection, refer to "2.2.5 Frame Ground Connection".

Safety Instructions

Each PSU complies with Safety Class 1 of IEC60950, EN60950, UL60950,
CAN/CSA-C22.2 No.60950, and AS/NZS60950; therefore a protective earth connection exists between the
mains outlet ground and the PSU case. To ensure the PBX chassis is safely grounded, it is essential that
the PSU case be securely fastened to the PBX chassis with the 4 screws provided with each PSU.
When installing or replacing PSU, basic safety precautions should always be followed to reduce the risk of
fire, electric shock and injury to persons, including the following:
1.
Never install or replace PSU during a lightning storm.
2.
Never install or replace PSU in wet locations.
3.
Never install or replace PSU unless at least 20 s has elapsed after the AC supply is disconnected.
42
Installation Manual
Lower/Upper Input Voltage Range
Lower: 100 V AC to 130 V AC
Upper: 200 V AC to 240 V AC
Lower: 100 V AC to 130 V AC
Upper: 200 V AC to 240 V AC
Lower: 100 V AC to 130 V AC
Upper: 200 V AC to 240 V AC
PSU-S
Current
1.4 A
0.8 A
2.5 A
1.4 A
5.1 A
2.55 A
PSU-M/PSU-L
Ground Terminal
Power Switch
AC Inlet
Input Frequency
50 Hz or 60 Hz