CDS 4000
quickly identify the error and correct it. This error
message will keep displaying until any key is

Setting up a large system

The central units are interconnected with the
control link cables in the D9-connectors NEXT
CU4005/CU4010 and PREVIOUS
CU4005/CU4010.
The first unit becomes MASTER and the others
will be SLAVES. A maximum of ten
CU4005/CU4010s can be linked together. Volume
control and set-up for the system can only be done
on the master or with MC4000 Microphone
Controller and personal computers (RS4232).
Connection of the microphone units in the chain is
done in the same way as described above for the
Manual no. 4479, Printed in Denmark, 02/03
pressed.
CU4005. The CU4010 allows connection of 100
microphone units, but please note that each chain
can control a maximum of 50 units. A maximum of
ten CM4000 Chairman Units can be used in the
system. They can be positioned anywhere in the
different microphone chains.
One or max. two MC4000 Microphone Control
units can be connected anywhere in the D9 control
link, i.e. between central units, at the first and/or
last unit. Do not, however, connect two MC4000s
in the same end of the control link without separate
power supply for one of the MC4000 units. If two
SYSTEM ENHANCEMENT