Yearly Maintenance (or every two tons) - Continued
Check for Air Leaks Around the Door, Glass, and Ashpan
!
Air leaks into the firebox will decrease the stove's performance greatly, leading to excessive
sooting, inefficient burning, and perhaps a malfunction.
Test the door seal by shutting the door on a dollar bill in various locations. If the bill can be easily
slid out, air may be leaking around the door seal – inspect the door gasket and door catch
carefully.
Inspect the door gasket to make sure it is fully attached. Use stove gasket cement to re-attach if
necessary. If the door gasket is worn or flattened, replace.
Check the door to make sure it latches correctly. Slight adjustments can be made to the door
catch if necessary (do not over-tighten this catch, an over-tightened catch will damage the door).
The latch should engage with a slight amount of resistance, yet not be difficult to engage.
If the glass is cracked, replace. The glass is held in place by glass clips that are underneath the
airwash brackets. See the illustration below for details.
Remove the ashpan and inspect the gasket around the perimeter of the ashpan. Re-attach, or
replace the gasket if necessary.
Replacement Parts
Blower, Combustion
Blower, Convection
Outside Air Kit
Travis Industries
Maintenance
Door
Door
Gasket
Attachment
Nuts
5/16"
Nutdriver
Airwash
Spacer
Glass Clip
Airwash Bracket
Glass (with
channel gasket)
93005535
98900755A
99200136
Door
Frame
Glass Clips
Airwash Spacers
Igniter
Knob, Air Control Cover
4 0 1 1 0 0 9
Door
Gasket
Airwash Brackets
99300149
91001606
9 3 5 0 8 1 2 6