"FAULT" Light

This light comes on when an error occurs:
The stove runs out of pellets
During initial start-up (for a split second) or for improper electrical frequency
A start-up sequence that does not result in the heater coming up to temperature
To reset the fault light, turn the mode switch to off and re-start the stove.

Power Outages

If a sustained power outage occurs while in "Manual", the stove will go to a "cool down" mode to
vacate smoke once power returns. If the power outage was short, the heater will go to the start-up
sequence. If in "Auto", the stove will re-start (if the room is cool).
!
Because this stove relies upon a blower to evacuate the smoke, some smoke may enter
the home during a power outage. To keep to a minimum, leave the door closed.