6. DIAG. TEST OPERATION

6.9 RAM CLEAR MODE (When using the operation panel)

6.9.1
Maintenance Counter Clear
Power OFF
DIPSW
6
OFF
Power ON
Power
Power
6.9.2
Parameter Clear
Power OFF
DIPSW
6
ON
Power ON
Power
Power
NOTE: Regarding the details of the maintenance counter and parameter settings after RAM clear, refer
to section 6.8 RAM CLEAR MODE.
: ON
: OFF
: BLINK
7
8
OFF
ON
[FEED], [PAUSE]
Online
Error
[PAUSE]
Online
Error
7
8
ON
ON
[FEED], [PAUSE]
Online
Error
[PAUSE]
Online
Error
6.9 RAM CLEAR MODE (When using the operation panel)
(1) Turn the power OFF.
(2) Set the DIP switches to enter the maintenance
counter clear mode.
(3) Turn the power ON while pressing and holding the
[FEED] and [PAUSE] keys.
(4) The printer enters the RAM clear mode.
(5) Perform the RAM clear, by holding [PAUSE] key.
(6) The RAM clear is completed, when all 3 LED's
blinks.
(7) Turn the power OFF.
(8) Set the DIP Switches to original position.
(1) Turn the power OFF.
(2) Set the DIP switches to enter the parameter clear
mode.
(3) Turn the power ON while pressing and holding the
[FEED] and [PAUSE] keys.
(4) The printer enters the RAM clear mode.
(5) Perform the RAM clear, by holding [PAUSE] key.
(6) The RAM clear is completed, when all 3 LED's
blinks.
(7) Turn the power OFF.
(8) Set the DIP Switches to original position.