When Using The Operation Panel - TEC B-450 SERIES Maintenance Manual

Hide thumbs Also See for B-450 SERIES:
Table of Contents

Advertisement

6. DIAG. TEST OPERATION

6.1.2 When using the operation panel

Power
Power
Power
: ON
: OFF
: BLINK
NOTES:
1. When an error occurs during printing, the error LED is lit and printing is stopped. The
error can be cleared by pressing the [PAUSE] key and the printer restores to the copy/
print tone selection. Auto-reissue is not performed after the error is cleared.
2. The default parameter at power on is as below:
•ISSUE COUNT: 1
•PRINT SPEED: 2 inch/sec.
•SENSOR: None
•TYPE: Batch
•LABEL LENGTH: 76mm (B-452-TS model) / 105 mm (B-452-HS model)
3. Even if the auto paper feed has been performed in online mode, an auto reverse feed
is not performed when starting a test print.
4. After a self diagnosis print, an auto reverse feed is not performed for printing the first
paper in online mode.
5. After the print head is raised and lowered, the auto paper feed is canceled.
6. Regarding the details of the self diagnosis print and test print, refer to sections 6.2 and
6.4, respectively. (Only slant lines (3 dot) are printed at the test print.)
Power ON
[PAUSE]
Online
Error
[FEED] or [PAUSE]
Online
Error
[FEED]
Online
Error
Power OFF
6.1 OUTLINE OF THE DIAG. TEST OPERATION
(1) Turn the power ON while pressing and holding
the [PAUSE] key.
(2) Self diagnosis is performed.
(3) Start a self diagnosis print.
• In case of thermal transfer print, press the
[FEED] key.
• In case of thermal direct print, press the
[PAUSE] key.
(4) Start the test print by pressing the [FEED] key.
(5) Turn the power OFF.
6-2
EO18-33003A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B-452-qp-pacB-452-hs

Table of Contents