To Access Pump & Brush Motor; Solution Valve Cable Adjustment; Spray Jet - Windsor Expert Instructions Manual

Windsor exp 115v electric carpet extractor
Hide thumbs Also See for Expert:
Table of Contents

Advertisement

TO ACCESS PUMP AND BRUSH MOTOR
1.
Situate machine in order to access bottom
cover. Remove screws (6) and bottom cover.
2.
To remove brush motor, loosen nuts at brush
motor and slide motor forward to reduce belt
tension. Remove belt. Continue loosening nuts
at brush motor until free from brush bracket.
Disconnect wires.
3.
To remove pump, loosen screws holding pump
mounting bracket to casting and remove as one
unit. Lift pump and mounting bracket up to
gain access to all hose clamps which need to
be removed before pump is free from machine.
Disconnect wires.

SOLUTION VALVE CABLE ADJUSTMENT

The solution valve cable has been factory set so that
action of the solution lever moves the valve from
fully closed to fully open. As the machine operates
the cable will stretch and the lever will not be able to
fully open the valve. The play in the solution lever
should be checked periodically and adjusted when
needed as described below.
1.
Loosen the lock nut at the point where the
cable enters the lever housing on the
machine handle.
2.
Turn the threaded end of the cable sleeve
to adjust. Threading the end further into the
housing will slacken the cable, increasing
the play in the lever. Threading the end out
of the housing will tighten the cable,
decreasing the play in the lever.
3.
Tighten the locking nut against the housing
after adjusting the play as required.
4.
If there is not enough thread adjustment
available, the cable length can be adjusted
directly at its connection to the solution
valve. This is accessed by removing the
back control panel.

SPRAY JET

Note: To prevent a clogged jet due to alkali build-up,
the spray system should be flushed with 1 to 2
gallons of clean hot water at the end of each day.
1.
Situate machine in order to access bottom
cover.
2.
The machine is equipped with a "Quick
Change" jet that can be easily removed for
cleaning. To remove- push jet in and rotate
1/4 turn.
3.
Wash jet and blow dry. Do not use pins or
wire to remove obstruction as this will change
spray pattern.
EXP 98363 08-25-04