Summary of Contents for MCZ PHILO COMFORT-AIR

  • Page 1 USE AND INSTALLATION MANUAL* *Some installation advice given in this manual could contravenes UK building regulations guidelines. A supplementary instruction manual in provided to give correct advice for installations within the UK” 8901144800...
  • Page 2 MCZ GROUP S.p.A. - Via La Croce 8, I - 33074 Vigonovo di Fontanafredda (PN) Italy. EN 14785 - 2006 Art. 15a B-VG / BImSchV / VKF AEAI Regensburger und Münchener BStV erfüllt. PHILO COMFORT-AIR Potencia nominal: 9,0 kW Potência nominal:...
  • Page 3: Table Of Contents

    OPERATING MODES ........................35     4.8. Manual and automatic ......................35     4.8.1. Going from manual to automatic mode ................35     4.8.1.1. Contents Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 4 Decommissioning (end of season) ....................56     Checking the internal components ....................56     6. FAULTS / CAUSES / SOLUTIONS ..................... 57   7. WIRING DIAGRAMS ........................59   Contents Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 5: Introduction

    Indicates a sequence of buttons to press to access the menu or perform adjustments. MANUAL Indicates that you should refer carefully to this manual or relevant instructions. Introduction Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 6: Warnings And Guarantee Terms

    Do not touch the stove with wet hands as the appliance is electrical. Always remove the cable before operating on the unit.  Before carrying out any cleaning or maintenance Warnings and guarantee terms Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 7: Operational Warnings

    MCZ's qualified, authorised personnel. If repairs are necessary, request original spare parts.  Use ONLY fuel indicated by MCZ (for ITALY only 6 mm Warnings and guarantee terms Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 8: Important Information For Correct Disposal Of The Product In Accordance With Ec Directive 2002/96/Ec

    The guarantee covers the replacement or free repair of parts recognised as being faulty at source due to manufacturing defects. Warnings and guarantee terms Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 9: Guarantee Limits

    MCZ's instructions (see relevant chapters in this use manual). MCZ cannot be held liable for any damage which may - either directly or indirectly - be caused to persons, animals or property ensuing from failure to observe all the instructions provided in the instruction manual and, specifically, the warnings regarding installation, use and maintenance of the device.
  • Page 10: Theoretical Recommendations For Installation

    Content: 100% untreated wood without any added fixing  substances (max. percentage bark 5%) Packaging: in bags made from environmentally friendly or  biologically decomposable material Theoretical recommendations for installation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 11: Installation Precautions

    The volume of the room should be no less than 30 m Theoretical recommendations for installation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 12: Connecting The External Air Inlet

     be positioned in such a way that it cannot become obstructed Theoretical recommendations for installation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 13: Connecting The Smoke Outlet Pipe

    YOU ARE ALSO ADVISED NOT TO EXCEED A LENGTH OF 6 METRES WITH A PIPE OF 80 mm DIAMETER Example of pellet stove installation Theoretical recommendations for installation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 14: Flue Pipe Connection

    This type of connection (even when there is a 1) Windproof chimney temporary loss of current) ensures that smoke is discharged. 2) Flue pipe 3) Inspection point Theoretical recommendations for installation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 15: Operating Faults Associated With Draught Defects In The Flue Pipe

    Precarious conditions can usually be resolved by setting the stove appropriately. This must be done by qualified MCZ staff. Theoretical recommendations for installation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 16: Installation And Assembly

    PELLET STOVES Chapter 3 USE AND MAINTENANCE MANUAL page 3. INSTALLATION AND ASSEMBLY SKETCHES AND TECHNICAL SPECIFICATIONS 3.1. PHILO COMFORT AIR dimensions 3.1.1. Installation and assembly Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 17: Technical Specifications

    Data that may vary depending on the type of pellet used.  **Heatable volume according to the cal/m requirement 40-35-30 (40-35-30 Kcal/h respectively for m  Product compliant with multiple flue installation. Installation and assembly Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 18: Preparation And Unpacking

    Figure 6 - Removing the packaging screws Figure 3 – Front panel package Figure 4 – Grille package Figure 5 – Upper top package Installation and assembly Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 19 1. Rotating the feet clockwise lowers the stove 2. Rotating feet anticlockwise raises stove Piedino J Foot J Installation and assembly Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 20: Connecting The Smoke Outlet Pipe

    T-union must be turned towards the back of the stove and the pre-perforated panel at the rear of the stove must be removed. Next, connect the pipes. Installation and assembly Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 21: Connecting The Hot Air Duct

    POSITION 4: AIR DUCTED POSITION 5: handle A - AIR DIFFUSED POSITION 6: handle B - AIR DIFFUSED POS.5 POS.1 POS.4 POS.3 POS.2 POS.6 Installation and assembly Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 22 It is advisable to make ducts similar in length to distribute the air in a uniform manner otherwise the hot air will opt for the shortest or straightest channel. Installation and assembly Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 23: Fitting The Cladding

    Open the door and place two more screws at the bottom). The screws to position in the centre (underneath the door) are black. Installation and assembly Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 24: Fitting The Upper Top

    The centring process is essential to the ability to direct the air in the desired position. 1- POSITION OF THE “TRIANGOLO” ∆ TOWARDS THE BACK OF THE STOVE Installation and assembly Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 25 PELLET STOVES Chapter 3 USE AND MAINTENANCE MANUAL page 2- POSITION OF THE handle STUD IN THE SAME POSITION AS THE "TRIANGLE" ∆ Installation and assembly Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 26: Fitting The Air Filter

    If the stove is not used for a period of time, remove the power supply cable from the stove. Electrical connection of the stove Installation and assembly Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 27: Operation

    Try to familiarise yourself with the controls shown on the panel or remote control. Try to visually memorise the messages that the stove shows you via the display on the remote control. Operation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 28: Check Prior To Start-Up

    The remote control is fitted with a bright blue backlight that is activated at the press of a button. Position of the room temperature sensor Operation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 29: Lcd Remote Control Keypad

    6. The MENU button allows you to access the ventilation, SLEEP mode and TIMER settings 7. Support base that contains the battery compartment Operation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 30: Remote Control Display

    TIMER is enabled. If the icon is fully on the TIMER setting 19 you are selecting the personalised weekly program (that mode is on. involves entering daily -> 24h time brackets) Operation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 31: Type And Replacement Of Batteries

    We recommend that you keep spare batteries in your home at all times. When replacing the batteries, note the polarity indicated by the symbols imprinted inside the remote control compartment. Operation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 32: Emergency Panel

    G. Button to enable communication between the stove and a new remote control (via the process explained below) TO ALLOW THE STOVE TO OPERATE WITH THE REMOTE CONTROL, SELECTOR "D" MUST BE SET TO "REMOTE" Operation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 33: Settings To Implement Before The First Start-Up

    After a start-up phase of about 15 minutes, the stove runs regularly. After the stove is shut down by pressing button3the cooling procedure begins. This includes suspension of fuel filling, cleaning of the brazier Operation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 34: Note Regarding First Start-Up

    MAXIMUM power is the 5 power level;  SHUTTING DOWN THE STOVE WITHOUT THE REMOTE CONTROL To shut down the stove move selector “D” to the OFF Operation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 35: Operating Modes

    In this operating mode the flame symbol is completely lit. 4.8.3. Automatic mode While MANUAL mode allows you to simply select the heat output delivered and keep this function unchanged over time, AUTOMATIC Operation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 36 Operation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 37: Automatic Mode With Eco-Stop

    You do not need to reset ECO STOP mode as it remains in the memory from the last time the stove was used. Operation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 38: The Hot Air Fan

    If low fan settings are selected the power of the stove will be automatically limited to prevent the structure and the air released by the room fans from overheating. Operation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 39: Sleep Function

    TH = Thursday FR = Friday SA = Saturday SU = Sunday The current day and time setting is essential for the correct operation of the timer. Operation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 40: Timer Activation And Selecting A Program

    To enable this option, follow the instructions above for the weekly program setting but instead of selecting one of the programs contained in the table of weekly programs (from P01 to P010) select program P99. PROGRAM Operation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 41 Take this time into consideration for considerable fuel savings. Operation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 42: Preset Weekly And Daily Programs

    For those with more specialised needs not satisfied by the ten weekly programs, weekly program P99 can be personalised using one of the 62 (see different daily programs for each individual day of the week chapter 4.11.2 Operation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 43: Pellet Stoves

    Sat‐Sun  Sab-Dom Mon‐Fri  Lun-Ven Sat‐Sun  Sab-Dom Mon‐Fri  Lun-Ven Sat‐Sun  Sab-Dom Mon‐Sat  Lun-Sab Sun  Mon‐Sat  Lun-Sab Sun  Mon‐Sat  Lun-Sab Sun  Fri  Sat‐Sun  Sab-Dom acceso on  off  spento Operation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 44: Daily Programs

    PELLET STOVES Chapter 4 USE AND MAINTENANCE MANUAL page Daily programs 4.12.2. Programmi Daily  Table of times  Tabella orari giornalieri programs  N° Operation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 45 PELLET STOVES Chapter 4 USE AND MAINTENANCE MANUAL page Programmi Daily  Table of times  Tabella orari programs  giornalieri N° Operation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 46: Practical Example Of Weekly/ Daily Programming

     only at home from 14:00 onwards Based on these times, we can select the daily programs that most closely meet this activity from the table illustrated in paragraph 4.12.2. Operation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 47 Tuesday symbol begins to flash. The dash indicates Tuesday symbol and the WE = Wednesday symbol that a timer program has been set for that day. will begin to flash. Operation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 48: Enabling The Keypad Lock

    After this time the "lock" symbol will appear at the top, left-hand side of the display to confirm that the keypad is locked. To disable the lock repeat the operation described above. Operation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 49: Synchronising The Remote Control

     FAILED START-UP If a flame fails to ignite during the start-up phase, the stove alarm is triggered. Operation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 50: Alarm Signals

    Check whether the pellet igniter heats up. Results from fire extinguishing due to lack of fuel (tank Abnormal fire extinguishing empty). Operation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 51 Regular maintenance advice before maintenance has expired and maintenance is due to be carried out. Contact a qualified MCZ technician. Operation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 52: Silencing Alarms

    (note that this operation is carried out by a specialised MCZ technician) Only once the cause of the shutdown has been permanently remedied stove restarted. Operation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 53: Maintenance And Cleaning

    2 or 3 days. When this operation is finished, reinsert the ash drawer under the brazier, checking that it is properly inserted. Maintenance and cleaning Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 54: Cleaning The Glazing

    Cleaning the PHILO stove T-union Maintenance and cleaning Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 55 Maintenance and cleaning Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 56: Decommissioning (End Of Season)

    Ash tray ● Glass ● Complete exchanger ● Smoke duct ● Door seal ● ● Air filter Remote control battery ● (if purchased/ optional) Maintenance and cleaning Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 57: Faults / Causes / Solutions

     Check the condition of the door seals.  Change the type of pellet.  Damp or unsuitable pellets.  Check the motor and replace it if  Smoke extractor motor broken. necessary. Faults/Causes/Solutions Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 58 MCZ personnel. The manufacturer will not be held liable and the guarantee will not be valid if this condition is not abided by. Faults/Causes/Solutions Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 59: Wiring Diagrams

    12. Air flow sensor 7. Smoke blower fan N.B. The electrical wiring of individual components is equipped with pre-cabled connectors, the measurements of which differ from one another. Wiring diagrams Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 60 MCZ GROUP S.p.A. Via La Croce 8 33074 Vigonovo di Fontanafredda (PN) – ITALY Telephone: +39 0434/599599 PBX Fax: +39 0434/599598 Internet: www.mcz.it e-mail: mcz@mcz.it 8901144800 Rev 0 07/2011...