Connecting The Smoke Outlet Pipe - MCZ PHILO COMFORT-AIR Use And Installation Manual

Pellet stoves
Table of Contents

Advertisement

It is not obligatory to connect the air inlet directly to
the stove (direct connection to the outside) but the
aforementioned
approximately 50 m³/h of air is provided.
See standard UNI 10683.

CONNECTING THE SMOKE OUTLET PIPE

2.5.
When making the hole for the smoke outlet pipe you must take note of
any flammable material. If the hole must pass through a wall made
from wood or thermolabile material THE FITTER MUST begin by using
the relevant wall connection minimum diameter 13 cm) and suitably
insulate the stove pipe crossing through it using appropriate insulating
materials (thickness of 1.3 - 5 with min. heat conductivity of 0.07
W/m°K).
This instruction is also relevant if the stove pipe must cross vertical or
horizontal sections close to the thermolabile wall (min. distance 20 cm).
Alternatively, we recommend the use of an insulated industrial pipe that
can also be used externally to prevent condensation.
The combustion chamber works under vacuum. The smoke duct
through which the smoke is discharged will be under vacuum when
connected to an efficient flue pipe, as specified.
Always use pipes and connections with appropriate
seals that guarantee air- and watertightness.
All sections of the smoke duct must be accessible for
inspection and removable (us a T-union with inspection
point). This makes it possible to clean the inside of the stove
regularly.
Position the stove taking note of all the specifications and warnings
underlined so far.
IMPORTANT!
All 90° changes of direction in the smoke outlet
channel must be prepared with suitable T-unions
with inspection points (see pellet stove accessories).
It is absolutely forbidden to place a net at the end of
the outlet pipe as this may cause the stove to
malfunction.
WHEN CONNECTING THE FLUE PIPE NO MORE THAN
2 - 3 METRES OF HORIZONTAL PIPING SHOULD BE
USED AND NO MORE THAN THREE 90° BENDS
SHOULD BE USED
YOU ARE ALSO ADVISED NOT TO EXCEED A LENGTH
OF 6 METRES WITH A PIPE OF 80 mm DIAMETER
Theoretical recommendations for installation
PELLET STOVES
USE AND MAINTENANCE MANUAL
section
must
ensure
that
1
1
Rear view of a pellet stove
1)
Smoke outlet
2)
Combustion air inlet via the holes on
the back of the stove
Example of pellet stove installation
Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited