Control Description; System - Rheem R-410A Installation Instructions Manual

Prl-jec series two-stage heat pump outdoor units
Hide thumbs Also See for R-410A:
Table of Contents

Advertisement

FIGURE 4
O.D. FAN (OFM) RELAY
ICC BOARD
{
COMPRESSOR
WIRING
CONNECTOR
LINE VOLTAGE
CONNECTION
12.0 CONDENSING UNITS EQUIPPED WITH THE
12.0
OMFORT ONTROL
The Comfort Control
(ICC) and is an integral part of the Comfort Control
2
features:
12.1 Control Description (see Figure 4)
Dual 7-Segment LED
• Displays status and diagnostic codes (See Status and Diagnostic Description)
• Displays diagnostic/fault recall (See Test Mode/Fault Recall)
Red LED (Y1)
• Y1 red LED (solid on) indicates Y1 call from thermostat is present
CAUTION
UNIT MAY START SUDDENLY AND WITHOUT WARNING
Solid red light indicates a thermostat call for unit operation is present at
the ICC control. ICC control will attempt to start unit after short cycle timer
expires or when in Active Protection mode will attempt to restart unit prior
to Lockout mode.
Line Voltage Connector
• Line voltage is connected to control board at lug terminals L1 & L2
• Maximum wire size accepted is 6 AWG copper wire
• # 4 – 6 AWG
45 in/lbs
# 8 AWG
40 in/lbs
# 10 – 14 AWG
35 in/lbs
(Check wire terminations annually)
Compressor Control (K2)
• Sealed single pole compressor relay switch with optical feedback feature (arc
detection)
ICC (INTEGRATED
COMPRESSOR CONTROL)
COMPRESSOR
CONTROL (K2)
2

SYSTEM™

is the next generation of the Integrated Compressor Control
LOW PRESSURE CONTROL INPUT
HIGH PRESSURE CONTROL INPUT
TEST BUTTON
SW2 BUTTON
System™ with the following
2
MEMORY CARD
LOW VOLT FUSE
THERMOSTAT
CONNECTION (E2)
RED LED (Y1)
AMBIENT DEFROST
CONTROL
DEFROST SENSOR
7-SEGMENT LED
17