Control Wiring

WARNING:
at the fuse box or service panel before making
any electrical connections. Also, the ground
connection must be completed before making line
voltage connections. Failure to do so can result in
electrical shock, severe personal injury, or death.
Control Wiring
Running low-voltage wires in conduit with line
voltage power wires is not recommended. Low-
voltage wiring may be run through the insulated
plastic bushing provided in the 7/8" [19 mm]
hole in the base panel, up to and attached to
the pigtails from the bottom of the control box.
Conduit can be run to the base panel if desired by
removing the insulated bushing.
A thermostat and a 24-volt, 40 VA minimum
transformer are required for the control circuit
of the system. The furnace or the air handler
transformer may be used if sufficient. See the
wiring diagram for reference. Use "Wire Size" table
on this page to size the 24-volt control wiring.
Do not use phone cord to connect indoor and
outdoor units and thermostat. This could damage
the controls and may not be adequately sized for
the control's electrical load.
TYPICAL
CONTROL WIRING FOR AIR HANDLER
*If maximum outlet temperature rise is
desired, it is recommended that W1 and
W2 be jumpered together.
Air Handler
WH/BL
W2
GR/BK
G
*
YL
Y
1
WH/BK
W1
*
B
BL
*
ODD
GR/YL
BR
*Not present on all
C
air-handler models.
RD
R
* 2
YL/BL
Y
WIRING INFORMATION
Line Voltage
-
Field Installed
-
Factory Standard
Turn off electric power
Heat Pump Thermostat
Optional Field Installed Jumper (see note 1)
B
Y G W2
E
C
OPTIONAL
- 1 STAGE HEAT
FIELD WIRE SIZE FOR 24-VOLT THERMOSTAT CIRCUITS
Thermostat
SOLID COPPER WIRE – AWG.
Load (amps)
3.0
18
16
2.5
18
16
2.0
18
16
20
50
[6]
[15]
Length of Run – Feet [m] (1)
(1) Wire length equals twice the run distance.
NOTICE: Do not use control wiring smaller than No. 18
AWG between thermostat and outdoor unit.
Typical Noncommunicating
Thermostat Wiring Diagrams
The following figures show the typical wiring
diagrams for (-)H2V air handlers and 2-stage
heat pump and dual fuel applications with a gas
furnace and 1-stage heat pump. Cooling and
heat pump airflows may need to be adjusted
for homeowner comfort once the system is
operational.
WIRE COLOR CODE
BK – BLACK
GY – GRAY
BR – BROWN
O – ORANGE
BL – BLUE
PR – PURPLE
G – GREEN
R – RED
R
Heat Pump
Outdoor Unit
YL
Y
BL
B
BR
C
R
RD
PR
D

WIRING

14
12
10
10
10
14
12
10
10
10
14
12
10
10
10
100 150 200
250 300
[30] [46] [51]
[76] [91]
W – WHITE
Y – YELLOW
NOTES:
1. Jumper "E" to "W2" on
thermostat to transfer
control of supplemental
heat to 1st stage when
the emergency heat
switch is on.
2. This wire turns on elec-
tric heat strip during
defrost, omit for most
economical operation.
WIRE COLOR CODE
BK = BLACK
BL = BLUE
BR = BROWN
GR = GREEN
PR = PURPLE
RD = RED
WH = WHITE
YL = YELLOW
23