Spa Maintenance

Proper and regular maintenance of your spa will help it retain its beauty
and performance. Your authorized Sundance dealer can supply you with
all the information, supplies and accessory products you will need to
accomplish this.

11.1 Cleaning The Filter

Your new spa is equipped with an exclusive MicroClean
cartridge located under the filter lid. Fine debris are filtered 24-hours
by the circulation pump drawing water through the ultra-fine (stage 2)
cartridge. Larger debris are filtered by the main 2-speed pump drawing
water through the (stage 1) polyester mesh (pleated) cartridge during
normal operation and during each filtration/heating cycle. Combined,
both filter halves work together to give you unsurpassed water quality
by trapping suspended particles on their outer surface. Note: To ensure
optimum performance, clean and reuse the stage 1 cartridge once a
month and replace the stage 2 cartridge every 3 months, or as needed.
All models include filters on their footwell suction covers (shown
right) that prevent debris from entering pump 2 and the massage
selector(s), when operating. These filters must remain in place
to protect these components from debris entrapment/damage.
They should be cleaned every 2 months, or when weak pump 2
performance is observed.
ALWAYS TURN POWER TO SPA OFF BEFORE CLEANINg THE
FILTER CARTRIDgE! Refer to the filter cleaning/replacement
procedure below:
A
A
B
B
Loosen filter nut to provide clearance, then
Loosen filter nut to provide clearance, then
remove filter assembly.
remove filter assembly.
Note: Remove and clean the Stage 1
Note: Remove and clean the Stage 1
D
D
filter cartridge once a month.
filter cartridge once a month.
TURN POWER TO HOT TUB OFF!
TURN POWER TO HOT TUB OFF!
C
C
Filter
Filter
Nut
Nut
1. Rotate stage 2 retainer counterclockwise
1. Rotate stage 2 retainer counterclockwise
2. Replace (throw-away) stage 2 filter after 3
2. Replace (throw-away) stage 2 filter after 3
Replace!
Replace!
2.
2.
1.
1.
Stage 2
Stage 2
filter
filter
to release, then separate filter assembly.
to release, then separate filter assembly.
months use or as needed. DO NOT REUSE!
months use or as needed. DO NOT REUSE!
Note: The Stage 2 filter cartridge cannot be
Note: The Stage 2 filter cartridge cannot be
E
E
cleaned and must be (thrown out) replaced
cleaned and must be (thrown out) replaced
every 3 months, or as needed.
every 3 months, or as needed.
2-stage filter
DO NOT
DO NOT
Reuse!
Reuse!
Stage 1
Stage 1
filter
filter
(Reuseable)
(Reuseable)