Culligan Premium Aqua-Cleer RO Installation And Operation Instructions Manual page 5

Premuim bottle-free cooler
Table of Contents

Advertisement

Prepare and Flush Water Treatment Components
CAUTION!
Activity
Verify system includes Air Gap (44403001 or
equivalent) for system drain
Flush the carbon block filter to drain for at least five
(5) minutes until there are no more carbon fines
observed.
Activate the Preferred Series 250 cartridge and
thoroughly flush per the detailed instructions.
Flush the pre-carbon filter and sediment filters to
drain
Flush the RO cartridge to a drain with chlorine-
free, filtered softened water for 24 hours prior to
installation
Flush the carbon post filter to drain
Prepare and Flush Cooler for Service
Activity
Unpack the Premium Cooler.
Inspect the Premuim Cooler for any shipping
damage.
Clean and sanitize the internal storage tank.
Flush and test the Premium Cooler.
See the appendixes for detailed instructions to perform these activities.
Cat. No. 01021717
All RO Membranes will require a 24-hour flush to drain. All flushing of mem-
branes and filters must be done with chlorine-free, filtered, softened water.