12. Plug in the power cord. The unit will refill with fresh water.
13. Unplug and drain the unit again. Continue filling and draining until there is no remaining chlorine odor.
14. When chlorine is no longer detected, fill with water and flush 3 gallons from the hot and cold faucets. Flush 1
gallon from the room temperature faucet.
Remove the Sanitizing Filter
1.
Unplug the unit and turn off the water supply.
2.
Remove the sanitizer cartridge from EZ head.
3.
Remove all bypass plugs from the heads or the empty housings on an AC 30 RO configuration.
Replace the Filters
4.
Install new filters.
NOTE
The preparation of all filters and RO cartridges must be done strictly in accordance with the instruc-
tions included in the Appendix section of this manual.
5.
Reconnect the carbon post filter.
6.
Connect the UV wire left disconnected.
7.
Plug in the power cord.
CAUTION!
NOTE
Do not turn on Red Power Switch yet.
Flush and Return Unit to Service
1.
Slowly turn ON the water supply.
2.
As the reservoir fills, depress and hold the Hot unlock button followed by the Hot dispense button and verify that
water dispenses from the faucet.
NOTE
Because it will take 3-5 hours for the RO system to fill the reservoir, take along a few jugs of freshly
prepared RO water from your shop to fill the reservoir for faster rinsing.
3.
Depress and hold the Cold dispense button until water dispenses from the faucet.
4.
Depress and hold the Room dispense button until water begins to flow.
Important! Ensure hot tank is not empty before turning on unit.
5.
Turn ON the Red Power Switch to start the chilling and heating processes.
6.
Verify that the compressor and heater are both working: place a hand on top of the compressor to feel for vibra-
tion, then dispense water from the hot tank (after five minutes), noting a temperature increase in the water.
7.
Visually inspect for proper operation of all floats and leak controller.
Culligan® Premium Cooler
16
The unit is now live. Take suitable safety precautions.